Nice E EDGE XSI 0620 LDC Instructions And Warnings For Installation And Use page 9

Tubular motor
Hide thumbs Also See for E EDGE XSI 0620 LDC:
Table of Contents

Advertisement

A.2 - Temporarily deactivating (and reactivating) motors you do not wish to program
A
NOTES AND WARNINGS
• This procedure temporarily deactivates (for 5 minutes) only motors whose up and down limit switches have already been programmed.
A.2.1 - To temporarily deactivate motors you do not wish to program
1
= 5 sec
ESC
Hold down the but-
release it after 5 sec-
onds;
ton and
A.2.2 - To reactivate temporarily locked out motors
You can reactivate the motors in two ways:
1
After 5 minutes the
locked out motors are
automatically reactivat-
ed by the system.
Wait for 5 minutes ...
A.3 - MANUAL programming of the UP ("0") and DOWN ("1") limit switches
A
NOTES AND WARNINGS
• This procedure is obligatory only for awnings without a mechanical stop at the Up position.
• This procedure can be used if the limit switches have been programmed using the semiautomatic procedure (A.4).
• After the limit positions have been programmed, the awning can be controlled by simply pressing the appropriate buttons on the control unit. The awning will move
between the positions set with procedures A.3.1 and A.3.2.
A.3.1 - To program the UP limit switch ("0")
1
(x 1)
2
PRG
Press and release
count 2 movements.
the button (1 time);
 3
" 0 "
... release the button as soon as the awning
reaches position "0" ( UP limit switch).
" 0 "
ESC
you will see a brief down
movement and a movement
which stops the awning at
the Up limit "0".
end
... the system will then
move the awning to
the mid position.
2
= 5 sec
Hold down the but-
release it after 5
ton and
seconds;
4
Finely adjust-
ing the posi-
tion of limit
switch "0"
Press the buttons until you reach the desired position.
Alternatively, for more accurate adjustment, run pro-
cedure B.1.
2
The system locks out only those motors whose limit
switches have already been programmed. It has no effect
on motors which have not yet been programmed.
The deactivation is temporary and lasts for 5 min-
utes.
For a period of 5 minutes, the locked out motors will not re-
spond to commands.
1
During the 5 minute
period the locked out
motors can be reacti-
vated at any time by the
user.
During the 5 minutes, at
... hold down the
any time...
button and
2
count 2 movements.
5
" 0 "
Hold down the
button and
end
= 10 sec
ESC
ESC
release it after 10
seconds;
3
continues
Command
an UP
movement
Hold down the button and wait...
= 5 sec
release it after 5
count 3 movements.
seconds;
end
the system will then
move the awning to
the mid position.
end
3
English – 8