Download Print this page
Nice NX FIT MZ 2017 SH BD Instructions And Warnings For Installation And Use

Nice NX FIT MZ 2017 SH BD Instructions And Warnings For Installation And Use

Tubular motor
Hide thumbs Also See for NX FIT MZ 2017 SH BD:

Advertisement

Quick Links

Nice
NX FIT MZ 2017 SH BD
Tubular Motor
EN - Instructions and warnings for installation and use

Advertisement

loading

Summary of Contents for Nice NX FIT MZ 2017 SH BD

  • Page 1 Nice NX FIT MZ 2017 SH BD Tubular Motor EN - Instructions and warnings for installation and use...
  • Page 2: Installation Warnings

    GENERAL WARNINGS: SAFETY - INSTALLATION - USE (original instructions in Italian) ATTENTION Important safety instructions. Follow all instructions as improper installation may cause serious damage ATTENTION Important safety instructions. It is important for you to comply with these instructions for your own and other people’s safety.
  • Page 3: Product Description And Intended Use

    Wireless technology makes even initial programming simple and user- friendly. • it is compatible with all Nice control electronics using the NRC radio system (trans- INSTALLATION OF THE MOTOR AND mitters and climate sensors, the latter can only be used if the motor is configured THE ACCESSORIES for operation in ONE-WAY mode);...
  • Page 4: Programming And Adjustments

    PROGRAMMING AND ADJUSTMENTS tion could cause severe physical injury. To assemble and install the motor, refer to fig. 3. Moreover, consult the Nice product catalogue or go to www.niceforyou.com to choose the crown of the limit switch (fig. 4.1 - TWO-WAY and ONE-WAY operation.
  • Page 5 Support for fixing the motor head. Cap for fixing the roller to the bracket (not included). Removing the connector if necessary 10 mm English – 4...
  • Page 6: General Warnings

    • The limit switch must be adjusted after installing the motor in the roller shutter and connecting it to the power supply. • Procedures that can only be completed with a Nice “ERA P” or “ERA W” • Comply strictly with the time limits indicated in the procedures: after releasing a key, transmitter having the PRG and ESC keys, or with transmitters equipped you have 60 seconds to press the next key indicated in the procedure;...
  • Page 7 Communication mode (ONE-WAY or TWO-WAY) GENERAL WARNINGS RELATING TO THE PROCEDURES • Before starting any programming, move the roller shutter to an intermediate position, away from the Up and Down limit switches. • When the motor is powered up, if it makes 2 movements this means that: at least one transmitter has been memorised and no limit switch has been programmed;...
  • Page 8 –– GROUP “A” PROCEDURES –– for motors configured for TWO-WAY communications Procedures which can only be completed with a Nice transmitter with the ▲, ■, ▼, PRG, ESC keys (eg. “ERA P BD”, “ERA W BD”) GENERAL WARNINGS RELATING TO THE PROCEDURES •...
  • Page 9 !!! (x 1) Observe the same roller shutter and, at the start of the movement will count 3 movements. a DOWN movement, stop the movement IMMEDI- stop; ATELY, by pressing and releasing the button (1 time): A.2 - Temporarily deactivating (and reactivating) motors you do not wish to program BiDi NOTES AND WARNINGS •...
  • Page 10 A.3 - MANUAL programming of the UP (“0”) and DOWN (“1”) limit switches BiDi NOTES AND WARNINGS • This procedure is obligatory only for roller shutters without a mechanical stop at the Up position. • This procedure can be used if the limit switches have been programmed using the semiautomatic procedure (A.8). •...
  • Page 11  continues “ 0 ” Command Command an UP an DOWN movement movement   ... lift the roller shutter up to the upper release the button. ▲ ▼ ▼ ▲ Hold down the button ) and wait ... Hold down the button ) and wait ...
  • Page 12 A.6 - MANUAL programming of the UPPER limit switch (“0”) and AUTOMATIC program- ming of the LOWER limit switch (“1”) BiDi NOTES AND WARNINGS • Use this procedure only for roller blinds equipped with a terminal bar that’s heavy enough to make the blind taut and that must rest on the floor. •...
  • Page 13 A.7 - Programming an INTERMEDIATE POSITION (position “H”) BiDi NOTES AND WARNINGS • This procedure memorises an intermediate position (position “H”) between the Up (“0”) and Down (“1”) limit switch positions. When the automation is being used, after giving the intermediate position command, the system will automatically stop the roller shutter at the programmed “H” position. •...
  • Page 14 A.9 - “RDC” Function: adjustment of the motor traction force when closing BiDi NOTES AND WARNINGS • This function prevents the excessive traction of the canvas at the end of the closing manoeuvre. During the final phase of this manoeuvre, the function automatically reduces the motor traction torque, based on the factory setting or the one adjusted by the installer with the following procedure.
  • Page 15 A.11 - “FRT” Function: automatic tensioning of the canvas when opening awnings that are not fitted with a mechanism to lock the awning when opening BiDi • Warning! – The FRT function cannot be activated if the FTC or FTA function has already been activated. •...
  • Page 16  5 = 1 sec sec. Hold down the but- count 3 movements. release the button. Hold down the but- count 4 movements. release the button. ton and ton and = ... “ 1 ” = 5 sec “1” “S” “S”...
  • Page 17 A.14 - Programming the movement (Ascent or Descent) that the motor must perform automatically when it starts to rain (ref. paragraph 6.1.2) BiDi  4 = 1 sec = 1 sec Move the awning to Hold down the but- count 2 movements release the button.
  • Page 18 A.15 - TOTAL or PARTIAL deletion of memory BiDi NOTES AND WARNINGS • In order to carry out the following deletion procedures, the transmitter must be memorised in mode I. • To change the motor’s configuration (from TWO-WAY to ONE-WAY), after completing the “FULL deletion of the memory” procedure, it is necessary to switch the mo- tor off and then on again.
  • Page 19 GENERAL INFORMATION ABOUT PROCEDURES “A.16”, “A.17”, “A.18” The “Roller shutter cruising speed (procedure A.16)”, “Total manoeuvre duration (procedure A.17)” and “Adjustment of the Soft-Start / Soft-Stop movement (procedure A.18)” functions can be used to fully customise every aspect of the roller shut- ter’s movement, including alignments and other effects that are useful especially when multiple roller shutters are installed close to one another, with different sizes and rollers of different diameters, or for making the shutter’s movement more silent.
  • Page 20 A.17 - Adjusting the total manoeuvre duration BiDi NOTES AND WARNINGS • This adjustment can only be done if the limit switches (“0” and “1”) have already been programmed. • The value set with this procedure, together with the “acceleration/deceleration” setting (procedure A.18) gives the cruising speed. To assess whether the resulting cruising speed is compatible with the roller shutter’s characteristics (weight, roller dimensions, torque required, etc.), consult the “Technical specifications”...
  • Page 21 –– GROUP “B” PROCEDURES –– for motors configured for ONE-WAY communications procedures which can only be completed with a Nice “ERA P” or “ERA W” transmitter with the ▲, ■, ▼, PRG, ESC keys GENERAL WARNINGS RELATING TO THE PROCEDURES •...
  • Page 22 B.2 - Locking and unlocking the motor’s memory MONO NOTES AND WARNINGS • Locking the motor’s memory stops any other (unscheduled or unauthorised) transmitters being memorised in it.  4 (x 1) (x 1) (x 1) Press and release count 2 movements. Press and release count 2 movements.
  • Page 23 B.3.2 - To program the DOWN limit switch (“1”)  continues (x 1) = 5 sec Comandare una manovra di DISCESA  Press and release count 2 movements. Hold down the but- release it after 5 count 2 movements. ▼ ▲...
  • Page 24 B.5 - AUTOMATIC programming of the UPPER limit switch (“0”) and MANUAL program- ming of the LOWER limit switch (“1”) MONO NOTES AND WARNINGS • Use this procedure solely for roller shutters with mechanical Up “0” limit switch stop. • Programme the UP limit switch (0) FIRST. •...
  • Page 25  5 Finely adjust- = 5 sec “ 0 ” ing the posi- tion of limit switch “0”  release it after 5 sec- Hold down the but- count 2 movements. Press the buttons until you reach the desired position. ton and onds;...
  • Page 26 “ESC” buttons (like “ERA P” and “ERA W” transmitters). • To run procedure B.8.2 you must have a new transmitter to memorise, chosen from the “Nice Screen” catalogue , and an old previously memorised transmitter. B.8.1 - To memorise the transmitter buttons in “Mode I” (“Standard mode”) •...
  • Page 27 B.9 - RDC” Function: adjustment of the motor traction force when closing MONO NOTES AND WARNINGS • This function prevents the excessive traction of the canvas at the end of the closing manoeuvre. During the final phase of this manoeuvre, the function automatically reduces the motor traction torque, based on the factory setting or the one adjusted by the installer with the following procedure.
  • Page 28 B.11 - “FRT” Function: automatic tensioning of the canvas when opening awnings that are not fitted with a mechanism to lock the awning when opening MONO • Warning! – The FRT function cannot be activated if the FTC or FTA function has already been activated. •...
  • Page 29  5 = 1 sec sec. Hold down the but- count 3 movements. release the button. Hold down the but- count 4 movements. release the button. ton and ton and = ... “ 1 ” = 5 sec “1” “S” “S”...
  • Page 30 MONO NOTES AND WARNINGS • To run this procedure you need the climate sensor you want to memorise, chosen from the “Nice Screen” catalogue, and an old transmitter memorised in Mode I (see par. 4.6.1). • When performing the procedure, you can cancel the programming at any time by holding down ■ and ▼ together for 4 seconds. Alternatively, do not press any keys and wait 60 seconds for the motor to perform 6 movements.
  • Page 31 B.16 - TOTAL or PARTIAL deletion of memory MONO NOTES AND WARNINGS • In order to carry out the following deletion procedures, the transmitter must be memorised in mode I. • To change the motor’s configuration (from TWO-WAY to ONE-WAY), after completing the “FULL deletion of the memory” procedure, it is necessary to switch the motor off and then on again.
  • Page 32  7 = 5 sec Hold down the button and; release them after 5 sec- onds; < – – – – – – – – – – Within 10 seconds – – – – – – – – – – > Run procedure B.16.1.
  • Page 33 GENERAL INFORMATION ABOUT PROCEDURES “B.17”, “B.18”, “B.19” The “Roller shutter cruising speed (procedure B.17)”, “Total manoeuvre duration (procedure B.18)” and “Adjustment of the Soft-Start / Soft-Stop movement (procedure B.19)” functions can be used to fully customise every aspect of the roller shut- ter’s movement, including alignments and other effects that are useful especially when multiple roller shutters are installed close to one another, with different sizes and rollers of different diameters, or for making the shutter’s movement more silent.
  • Page 34 B.18 - Adjusting the total manoeuvre duration MONO NOTES AND WARNINGS • This adjustment can only be done if the limit switches (“0” and “1”) have already been programmed. • The value set with this procedure, together with the “acceleration/deceleration” setting (procedure B.19) gives the cruising speed. To assess whether the resulting cruising speed is compatible with the roller shutter’s characteristics (weight, roller dimensions, torque required, etc.), consult the “Technical specifications”...
  • Page 35 DOWN for motors configured for ONE-WAY communication mode feasible only with a Nice transmitter equipped with buttons ▲, ■, and ▼ alone and lacking the PRG and ESC buttons GENERAL WARNINGS RELATING TO THE PROCEDURES • Before starting any programming, move the awning to an intermediate position, away from the Up and Down limit switch- •...
  • Page 36 “ESC” buttons (like “ERA P” and “ERA W” transmitters). • To run procedure C.2.2 you must have a new transmitter to memorise, chosen from the “Nice Screen” catalogue , and an old previously memorised transmitter. C.2.1 - To memorise the transmitter buttons in “Mode I” (“Standard mode”) •...
  • Page 37 DOWN NOTES AND WARNINGS • To run this procedure you need the climate sensor you want to memorise, chosen from the “Nice Screen” catalogue, and an old transmitter memorised in Mode I (see par. 4.6.1). • When performing the procedure, you can cancel the programming at any time by holding down ■ and ▼ together for 4 seconds. Alternatively, do not press any keys and wait 60 seconds for the motor to perform 6 movements.
  • Page 38 = 5 sec sec. Hold down the but- count 3 movements; release the button. On the transmitter to be deleted: hold down count 5 movements. ton and any key either the key memorised in mode 2 or the climatic conditions sensor; sec.
  • Page 39 Regolare con “ 0 ” precisione la quota del fine- sec. corsa “0”  Press the buttons until you reach the desired position. Hold down the count 3 movements; release the button. button and C.5.2 - To program the DOWN limit switch (“1”) ...
  • Page 40  4 “ 0 ” sec. Hold down the wait for the roller shutter to start rising; If the roller shutter starts in the opposite direction, press and release release the but- button and the motor will disengage automatically once the ton.
  • Page 41 Regolare con “ 1 ” precisione la quota del fine- sec. corsa “1”  Press the buttons until you reach the desired position. Hold down the count 3 movements; release the button. button and C.8 - MANUAL programming of the UPPER limit switch (“0”) and AUTOMATIC program- ming of the LOWER limit switch (“1”) MONO STOP...
  • Page 42 C.9 - Programming an INTERMEDIATE POSITION (position “H”) MONO STOP DOWN NOTES AND WARNINGS • This procedure memorises an intermediate position (position “H”) between the Up (“0”) and Down (“1”) limit switch positions. When the automation is being used, after giving the intermediate position command, the system will automatically stop the roller shutter at the programmed “H” position. •...
  • Page 43 C.10 - “RDC” Function: adjustment of the motor traction force when closing MONO STOP DOWN NOTES AND WARNINGS • This function prevents the excessive traction of the canvas at the end of the closing manoeuvre. During the final phase of this manoeuvre, the function automatically reduces the motor traction torque, based on the factory setting or the one adjusted by the installer with the following procedure.
  • Page 44 C.12 - “FTC” Function: tensioning the canvas when open awnings fitted with an auto- matic hooking and unhooking mechanism of the awning when opening MONO STOP DOWN • Warning! – The FTC function cannot be activated if the FRT or FTA function has already been activated. If the LOWER limit switch has been set to AUTOMATIC, the FTC function cannot be activated.
  • Page 45 C.13 - “FTA” Function: tensioning the canvas when open awnings fitted with a manual hooking and unhooking mechanism of the awning when opening MONO STOP DOWN • Warning! – The FTA function cannot be activated if the FRT or FTC function has already been activated. If the LOWER limit switch has been set to AUTOMATIC, the FTA function cannot be activated.
  • Page 46 C.14 - Programming the movement (Ascent or Descent) that the motor must perform automatically when it starts to rain (ref. paragraph 6.1.2) MONO STOP DOWN NOTES AND WARNINGS • When performing the procedure, at any time you can cancel it by keeping the ■ and ▼ keys pressed simultaneously for 4 seconds. Otherwise, do not press any key and wait 60 seconds for the motor to perform 6 movements.
  • Page 47: Optional Accessories

    It is equally important to be able to set the automation’s stop position in relation to the circumstances (sunshine, rain, etc.). If the automation is controlled with a Nice transmitter equipped with a “slider” sur- 5.1 - Maximum continuous work cycle face (e.g.
  • Page 48 Example: 1) The awning is open. 2) It starts raining. 3) The awning closes. 4) The user forces it to open after a few moments. 5) The awning opens again. 6) 15 minutes after being opened, the awning closes again automatically. 7) It stops raining for at least 15 minutes.
  • Page 49: Technical Characteristics

    Finally, try to supply the opposite electrical phase. 20° C (± 5° C). • Nice S.p.A. reserves the right to apply modifications to products at any time when deemed necessary, maintaining the same intended use and func- q When sending a Raise command, the motor does not start: tionality.
  • Page 50 Nice SpA Via Callalta, 1 31046 Oderzo TV Italy www.niceforyou.com info@niceforyou.com...