Controller Assemblies; Ordering And Configuration Guide - nvent 910 Series Installation, Operating And Maintenance Instructions

Table of Contents

Advertisement

1.5 CONTROLLER ASSEMBLIES

1.6 ORDERING AND CONFIGURATION GUIDE

Description
RAYCHEM 910 controller in an 8" x 10" FRP enclosure with
window. 2-pole 30 A EMR. Controls a single circuit with a
2-pole electromechanical relay.
(Approved for ordinary areas only)
RAYCHEM 910 controller in an 8" x 10" FRP enclosure with
window. 2-pole 30 A EMR. Controls a single circuit with a
2-pole electromechanical relay.
Includes an isolated 2-wire RS-485 communication option.
(Approved for ordinary areas only)
RAYCHEM 910 controller in an 8" x 10" FRP enclosure with
window. 2-pole 30 A 277 V SSR. Controls a single circuit with
a 2-pole solid-state relay.
(Approved for Class I, Div. 2 areas)
RAYCHEM 910 controller in an 8" x 10" FRP enclosure with
window. 2-pole 30 A 277 V SSR. Controls a single circuit with
a 2-pole solid-state relay. Includes an isolated 2-wire RS-485
communication option. (Approved for Class I, Div. 2 areas)
nVent RAYCHEM Supervisor Software
It includes indicators for alarm and output status and an integral Operator Console. An internal
connector is provided to plug in an optional communications interface.
The Control Module packaging provides a rugged, vibration-proof design.
Temperature sensor, communications, and alarm control wiring are connected to the
lever-operated spring terminals, providing gas-tight, vibration-resistant connections.
A large, easy-to-read alphanumeric display and menu-driven interface eases controller
con- figuration and eliminates the need for an external programmer. Access is available for
all monitored parameters, programmed values, and alarm information. Enhanced security is
provided by password protection.
Single phase current monitoring, ground fault detection, and voltage monitoring are provided.
The nVent RAYCHEM 910 Control Module also incorporates a universal power supply, allowing
operation directly from 100 to 277 Vac.
1.4.2 COMMUNICATIONS INTERFACE
In applications where the user wishes remote configuration capability, or wants to
communicate trace information and/or alarms to another device such as a Group
Communications Controller (780 Series/GCC-9000), an optional communications interface
may be installed in the Control Module.
A modem version that maintains compatibility with legacy products is available, or other
industry-standard interfaces such as nVent RAYCHEM RS-232 and RS-485 may be specified.
Two standard assemblies are available and stocked at the Factory:
1. An SSR version for use in ordinary or Class I, Division 2 areas
2. An EMR version for use in ordinary locations only
NVENT RAYCHEM 910 CONTROLLERS – FACTORY INVENTORY
RAYCHEM 910 CONTROLLERS – MADE-TO-ORDER (Contact factory for lead time)
Catalog Number
910*E1FWL*EMR2
910*E1FWL*EMR2*485
910*E1FWL*SSR2
910*E1FWL*SSR2*485
RAYCHEM Supervisor
Part Number
10170-001
10170-015
10170-002
10170-016
10391-002
nVent.com | 7
Weight
15
15
20
20
1