Output Signals - YOKOGAWA Total Insight series Quick Reference Instruction Manual

Total insight coriolis mass flow and density meter
Table of Contents

Advertisement

Transmitter

7.4.5 Output signals

Galvanic isolation
All circuits for inputs, outputs and power supply are galvanically isolated from each other.
Active current
One or two current outputs are available depending on MS code position 13.
output lout
Depending on the measured value, the active current output delivers 4 – 20 mA.
It may be used for output of the following measured values:
▪ Flow rate (mass, volume, net partial component flow of a mixture)
▪ Density
▪ Temperature
▪ Pressure
▪ Concentration
For HART communication devices, it is supplied on the current output lout1. The current
output may be operated in compliance with the NAMUR NE43 standard.
Nominal output current
Maximum output current range
Load resistance
Load resistance for secure HART communication
Additive maximum deviation
Additive output deviation for deviation from 20 °C ambient
temperature
ROTAMASS
Fig. 23: Active current output connection lout HART
Iout+
Iout-
Receiver
IM01U10A00-00EN-R, 2nd edition, 2017-08-29
Quick Reference Instruction Manual
Value
4 – 20 mA
2.4 – 21.6 mA
≤ 750 Ω
230 – 600 Ω
8 µA
0.8 µA/ °C
1
Wiring
39 / 54