Wiring
Fig. 16: Connection terminal circuits (transmitter on the left side, sensor on the right side)
1
2
3

7.3 Connecting cable

With remote type flow meters, sensors and transmitters are connected by means of con-
necting cables.
In order to obtain optimum measuring results and ensure compliance with the specifica-
tion, it is imperative that an original connecting cable from Rota Yokogawa is used. In or-
der to ensure the IP code, the cable must be professionally installed at the entries using a
cable gland. If necessary, the cable may be shortened using the enclosed assembly kit.
Fig. 17: Structure of connecting cable
1
2
3
If the connecting cable included in the delivery is too short, additional lengths can be pro-
cured through the Yokogawa sales organization.
32 / 54
1
2 3 4
Driver circuit
Sensor circuits
Temperature measurement circuits 6
1
2
3
Cap
Connecting cable
Clamp part
IM01U10A00-00EN-R, 2nd edition, 2017-08-29
5
6
4
Signal grounding
5
Transmitter
Sensor
4
5
6
4
Outer cable shield
5
Screw part
6
Housing cable entry
Connecting cable
3
2
1