Transmitter
Risk of injury due to electrical shock
WARNING
▶ The transmitter must be assigned an external, fixed-mount power switch or automatic
▶ The power switch of automatic circuit breaker must be installed near the transmitter
1. Switch off power supply.
2. Using an Allen wrench (Size: 3.0), remove the locking screw on the back cover in
3. Unscrew back cover from transmitter housing in counter-clockwise direction.
4. Attach cable glands.
5. Connect wires to connection terminals.
circuit breaker in order to disconnect the transmitter from the power grid (compliant
with IEC60947-1 and IEC60947-3). Power switch or automatic circuit breaker must
disconnect all lines under current, but cannot disconnect the grounding conductor
under any circumstances.
and easily accessible. The "OFF" switch position must be clearly recognizable.
clockwise direction.
IM01U10A00-00EN-R, 2nd edition, 2017-08-29
Quick Reference Instruction Manual
Wiring
47 / 54