1
PT-Series HD Camera Installation
1.5.2
Earth ground connection is very important
to protect PT-series from surge induced
failures and corrosion caused by stray
current/ground loops. Attach ground wire
(16 AWG or larger) to ground lug on
access panel. Use the large hex nut to
secure ground wire to stud on access
panel. Ground stud is #8-32 thread.
Caution!
When lifting the camera use the camera body and base, not the tubes.
PT-Series HD cameras must be mounted upright on top of the mounting surface, with the base below
the camera. The unit should not be hung upside down.
Not to scale
All dimensions in inches
Pan volume
minimum Ø25.5
2X 3.17 ± .02
0.295
2X 3.21 ± .02
427-0075-01-12 Version 110
Earth Ground Connection
0
Figure 1-2: PT-Series HD Camera Mounting
Ground Lug
0
Pan Axis
November 2017
4X Ø.354 THRU
Tilt Axis
8