1.6.3
The analog video connections on the back of the camera are BNC connectors. The camera also
provides an RCA video connector that can be used to temporarily monitor the video output.
The video cables used should be rated as RG59U or better to ensure a quality video signal.
Note
Insert the cable through the cable glands on the enclosure before terminating and connecting them.
In general, the terminated connectors will not fit through the cable gland. If terminated, it is possible
to make a clean and singular cut in the gland seal to install the cable into the gland seal.
1.6.4
The cable gland seal is designed for use with shielded Ethernet cable.
Note
Insert the cable through the cable glands on the enclosure before terminating and connecting them.
In general, the terminated connectors will not fit through the cable gland. If terminated, it is possible
to make a clean and singular cut in the gland seal to install the cable into the gland seal.
1.6.5
For serial communications, it is necessary to set the parameters such as the signaling standard (RS-
232 or RS-422), baud rate, number of stop bits, parity and so on. It is also necessary to select the
communication protocol used (either Pelco D or Bosch) and the camera address. By default, the serial
interface uses Pelco D, RS-422 standard, 9600 baud rate, 8/1/none, and address 1.
Note
Typical Bosch systems operate using a biphase connection. FLIR cameras do not accept biphase
signals directly. It may be necessary to install a biphase converter in order to use the Bosch protocol.
Connect the wires of the serial cable as show in
standard, ensure the transmit pair of the camera goes to the receive pair of the other device, and vice
versa.
Note
The terminal blocks for serial connections will accept a maximum 20 AWG wire size.
Note
The serial communications parameters for the PT-Series HD camera are set or modified either via
hardware DIP switch settings or via software, through a web browser interface. A single DIP switch
(SW103-9), Software Override determines whether the configuration comes from the hardware DIP
switches or the software settings.
Note
The DIP switches are only used to control serial communications parameters. Other settings, related
to IP camera functions and so on, must be modified via software (using a web browser).
427-0075-01-12 Version 110