Siemens 2000 Administration Manual page 79

Optipoint application module optipoint display module
Hide thumbs Also See for 2000:
Table of Contents

Advertisement

Description of functions
SRSR Switch To Standby Retry Count
SRSR TC_TEST Expiry Timeout
SRSR TC_TEST Retry Count
Subscriber Number
Subscriber Password
System Type
Maximum number of negative attempts for switching over to the
standby mode.
If all attempts fail, it will be changed to the home mode (standard
mode).
Valid value: 1 ... 255.
Standard value
page 96.
page 57
Required only if
Communication plattform is in standby mode (emergency mode).
Time period after which the next attempt of connection to the Main-
PBX will be started.
page 57
Required only if
Communication plattform is in standby mode (emergency mode).
Maximum number of positive attempts for switching over from stand-
by mode (emergency mode) to home mode (standard mode).
Standard-value
page 96.
page 57
Enter the subscriber number for the optiPoint 410/420 here.
The number can be 1 to 24 characters long.
This number is used as the internal telephone number.
page 24
page 55
This password allows you to transfer the subscriber number and the
configuration settings of your telephone to another telephone (mobile
logon).
Valid values: Alphanummerisch
Minimum length: 6 (for more information, see
Maximum length: 20
page 24
page 55
Select the type of the used communication platform here (read only).
page 55
SRSR Automatic Switch Back is activated.
SRSR Automatic Switch Back is activated.
Alphabetical Reference
Password Functions)
79