Troubleshooting
Fault no.
Error message displayed
710
• Vapour sensor defective
• Water pressure too low
• Water pressure too low
• No water in the waste trap
• Unit restarted after a
power failure
• WaveClean cancelled

7.3 Nameplate

96
Description
Vapour elimination is now only
controlled by the software. This
results in higher water
consumption.
As permanent error message
As sporadic error message
The waste trap is not filled with
sufficient water.
If there was no power failure in the
kitchen, it could be an operating
error. An example of this would be
unintentional switching on and off
during a running cooking program.
• Please observe the explanations and notes in the chapter on "Automatic
cleaning (WaveClean)"
When contacting Customer service, please always provide the
following data from the nameplate:
Serial number
(SN)
Type number
(TYP)
Operating instructions
Measure to be taken
• Contact Customer service
• Open the water valve
• If the water valve is not closed,
contact Customer service
• Activate fewer simultaneous wa-
ter consumers in the kitchen.
• Contact Customer service
• Open the water valve
• Pour water into the cooking zone
• If the error message persists,
contact Customer service
• Power failure < 1 minute
• Confirm the power failure mes-
sage
• Continue with the cooking pro-
gram
• No cleaning necessary
• Power failure > 1 minute
• Cooking program cancelled
• Perform cleaning