Selecting The Cleaning Level; Inserting The Cleaning Cartridge - Henny Penny FlexFusion PLATINUM COMBI Operation Manual

Hide thumbs Also See for FlexFusion PLATINUM COMBI:
Table of Contents

Advertisement

Cleaning and caring for the unit

6.11.2 Selecting the cleaning level

INFORMATION
INFORMATION
Tip
Requirement The unit is on

6.11.3 Inserting the cleaning cartridge

INFORMATION
INFORMATION
88
If the water pressure falls during cleaning, the cleaning program reverts to
maintenance status. When the water pressure is restored again, the cleaning
program runs automatically.
Despite different cleaning times, all cleaning levels required the same amount
of water.
In the case of automatic cleaning overnight, we recommend the "normal" or
"extra" cleaning levels. This ensures that there is sufficient drying.
Main menu is displayed
1. Tap Equipment function.
2. Tap the WaveClean symbol.
3. Select the cleaning level.
The Operating instructions window is displayed.
4. Tap the Confirm button.
The Select cleaning level window is displayed.
5. Tap the "START STOPP" button.
If necessary, the cooling zone is cooled down, until the
cleaning temperature of is reached.
Use only cleaning cartridges with an undamaged wax seal.
If the wax seal is damaged, the cleaner can enter the cleaning circuit prema-
turely or not dissolve completely, so that complete cleaning is no longer as-
sured.
Insert the cleaning cartridges only when requested to do so.
Never operate the unit in the automatic cleaning mode without a cleaning cart-
ridge.
If there is a high level of contamination, select the "extra" cleaning level and
use 2 cleaning cartridges.
Operating instructions