Program Data Input

There are a couple of items to note that can make the programming the Culligan MVP control a little easier. They are:
Slew Rates
This term refers to the speed at which the display moves through the input of material. For exam-
ple, holding down the "+" key for (5) seconds when inputting minutes for Time of Day will cause
the minutes to pass in (10) minute blocks of time. Pressing the "+" or "-" keys for shorter periods
(less than 5 seconds) will slow the rate. To move through the programming slowly, do not hold
down the "+" or the "-" keys.
Beeper
A beeper is available (normally on) to assist the user by providing an audible tone (about 70
decibels) to signify valid (one beep) and invalid (three beeps) key presses. The beeper can be
deactivated in the programming mode. (If error occurs, beep will still be ON even if set to "NO"
programming.)
Programming Mode
If there is no keypad activity for a (3) minute period while in the programming mode, the control-
Timeout
ler will exit the programming mode and return to a Time of Day display. Any setting that was
changed prior to the control timing out will revert back to the original value. Pressing the status
key saves the setting.
Program Input
For programming information to be accepted, the Status key must be depressed prior to Program-
Acceptance
ming mode timeout.
NOTE
Program steps marked with an asterisk (*) will be saved in EEPROM.
To begin programming, be sure all previous steps have been followed. Be sure power is supplied to the controller. Press
the Status key to begin and to move on from one completed programming step to another.
1.
Time of Day* - (Always available)
Establishes the current time of day. The display indicates "tod" as shown
in Figure 49 before changing to "12:00 PM".
To adjust the minutes or the hour setting, depress the Regeneration key
until the appropriate digits flash (Figure 50) then use the "-" or "+" keys
to scroll to the desired time. Pressing the "-" or "+" keys for 5 seconds
or more will cause the digits to scroll rapidly and at intervals greater than
one at a time. Pressing the Status key will save the setting and move to
the next programming step.
2.
Time of Regeneration* - (Delay mode only, DIP switch 4 off or DIP 4 on
when DIP 6 is off.)
For delayed regeneration purposes. The display indicates "tor" as shown
in Figure 51. The default time is 2:00 AM. This function is adjustable in
30-minute increments.
To adjust the minutes or the hour setting, depress the Regeneration key
until the appropriate digits flash then use the "-" or "+" keys to scroll to
the desired time. Pressing the "-" or "+" keys for 3 seconds or more will
cause the digits to scroll rapidly and at intervals greater than one at a
time. Pressing the Status key will save the setting and move to the next
programming step.
3.
Meter "K" Factor* - (Only active when a flow meter is attached)
Data input is the number of pulses a flow device emits to represents a
volume of water (gallons or liters). Initial display is "METEr" (Figure 52).
Refer to the information in
"K" factor for the flow-measuring device being used. The default setting is
50.0.
To adjust the "K" factor setting, depress the Regeneration key until the
appropriate digits flash (Figure 53) then use the "-" or "+" keys to scroll
to the desired setting. (Adjustable from 0.5 to 500). Pressing the "-" or "+"
keys for 3 seconds or more will cause the digits to scroll rapidly and at
intervals greater than one at a time. Pressing the Status key will save the
setting and move to the next programming step.