4.
Auxiliary Input Delay* - (All modes)
"AUX IN" (Figure 54) programming is required only if the AUX In terminal
is being used (Such as with a differential pressure switch). This estab-
lishes the uninterrupted period of time (in seconds) that a signal must
be received through the auxiliary input before the controller is to react
by initiating a regeneration sequence. The default time is (6) seconds.
Note that this feature is ignored if nothing is connected to the AUX input
terminal.
To adjust the seconds setting, use the "-" or "+" keys to scroll to the
desired number of seconds. (Adjustable from 0 to 999 seconds). Pressing
the "-" or "+" keys for 3 seconds or more will cause the digits to scroll rap-
intervals greater than one at a time. Pressing the Status
idly and at
key will save the setting and move to the next programming step.
5.
Cycle 1 Time* - (All modes)
The backwash cycle is represented by "bw 10" (Figure 55) in the display.
The default duration of cycle 1 is 10 minutes. To adjust the minutes set-
ting, use the "-" or "+" keys to scroll to the desired number of minutes.
(Adjustable from 1 to 99 minutes). Pressing the "-" or "+" keys for 3 sec-
onds or more will cause the digits to scroll rapidly and at intervals greater
than one at a time. Pressing the Status key will save the setting and move
to the next programming step.
6.
Cycle 2 Time* - (All modes except if Brine Reclaim DIP switch 10 is set
to ON)
The brine/slow rinse cycle is represented by "br 60" (Figure 56) in the
display. The default duration of cycle 2 is 60 minutes if the DIP switch #7
is OFF (softener) or 2 minutes if DIP switch #7 is ON (filter). To adjust the
minutes setting, use the "-" or "+" keys to scroll to the desired number of
minutes. Pressing the "-" or "+" keys for 3 seconds or more will cause the digits to scroll rapidly and at intervals
greater than one at a time. Pressing the Status key will save the setting and move to the next programming step.
7.
Cycle 3 Time* - (All modes)
The fast rinse cycle is represented by "Fr 10" (Figure 57) in the display.
The default duration of cycle 3 is 10 minutes. To adjust the minutes set-
ting, use the "-" or "+" keys to scroll to the desired number of minutes.
(Adjustable from 1 to 99 minutes). Pressing the "-" or "+" keys for 3 sec-
onds or more will cause the digits to scroll rapidly and at intervals greater
than one at a time. Pressing the Status key will save the setting and move
to the next programming step.
8.
Regeneration Interval* - Active only if no meter and/or Aqua-Sensor is
detected OR if DIP switch #6 is ON.
The display will show the REGEN icon and "days 03" (Figure 58) (if DIP
switch 8 is OFF) or REGEN and "Hour 12" if DIP switch 8 is ON.
The default setting for "days" is "03" while the "Hour" default is "12" (Fig-
ure 59).
To adjust the "day" or "Hour" setting, use the "-" or "+" keys to scroll
to the desired setting. (Adjustable from 1 to 99 days or 1 to 24 hours).
Pressing the "-" or "+" keys for 3 seconds or more will cause the digits
to scroll rapidly and at intervals greater than one at a time. Pressing the
Status key will save the setting and move to the next programming step.
NOTE
Single systems that are set with DIP switch 8 OFF and without a meter or Aqua-Sensor device con-
nected will offer the following OPTIONAL time clock setting to be displayed. (Figure 60)