Performance Data Sheet Culligan Gold Arsenic 10 - Culligan Gold Arsenic Series Owner's Manual

Water conditioner
Table of Contents

Advertisement

Culligan knows the more informed you are about your water treatment systems, the more confident you will be about
its performance. It's because of this and more than seventy years of commitment to customer satisfaction that Culligan is
providing this Performance Data Sheet to its customers.
Important Notice: Read this Performance Data Sheet and compare the capabilities of this unit with your actual
water treatment needs. It is recommended that before purchasing a water treatment unit, you have your water supply
tested to determine your actual water treatment needs.
Manufacturer:
Culligan International Company
9399 W. Higgins Rd., Suite 1100, Rosemont, IL 60018 USA
(847) 430-2800
Product:
Gold Arsenic 10"
Testing Conditions & Results:
Capacity: 75,000 gal (289,500 L)
Pressure: 60 psi
Temperature:
63°- 73° (17° - 23°C)
Service Flow:
5.0 gpm @ 6.0 psi, 19.3 Lpm @ 6.0 psi
Operating Conditions:
Operating Temperature Range:
Water Pressure Range:
Water Pressure Range (Canada):
Electrical Characteristics:
Substance Reduction
Testing was performed under standard laboratory conditions, actual performance may vary. This system has been
tested according to NSF/ANSI 53 for reduction of the substances listed below. The concentration of the indicated sub-
stance in water entering the system was reduced to a concentration less than or equal to the permissible limit for water
leaving the system, as specified in NSF/ANSI 53.
Model
Substance
Trivalent Arsenic pH 6.5
Trivalent Arsenic pH 8.5
Gold Arseinc
10"
Pentavalent Arsenic pH 6.5
Pentavalent Arsenic pH 8.5
The Culligan Gold Arsenic 10" has been tested and certified by WQA against NSF/ANSI Standard 372, CSA
B483.1, and NSF/ANSI Standard 53 for the reduction of arsenic (pentavalent and trivalent) up to 75,000 gallons.
The concentration in water entering the system was reduced to a concentration less than or equal to the permissible
limit for water leaving the system, as specified in NSF/ANSI 53.
Performance Indicator: If water flow decreases or a notable taste change occurs, the filter should be backwashed. If
conditions do not improve, contact your local Culligan Man. He can determine if your filter requires servicing. Do not
use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the
system. Refer to the specifications and warranty sections of this owners guide for more specific product information.
To avoid contamination from improper handling and installation, your system should only be installed and serviced by
your Culligan Man. Performance will vary based on local water conditions. The substances reduced by this product
are not necessarily in your water.
This system has been tested for the treatment of water containing pentavalent (also known as As(V), As(+5), or arse-
nate) and trivalent arsenic (also known as As(III), As(+3), or arsenite) at concentrations of 0.050 mg/L or less. This
system reduces both forms of arsenic below EPA MCL. Please see the Arsenic Facts section of the Performance Data
Sheet for further information.
The arsenic removal component of this system must be replaced at the end of its useful life of 75,000 gallons for the
Culligan Gold Arsenic 10" . The replacement of the removal component can be purchased from your local Culligan
dealer.
Buyer Signature
Seller Signature
33 - 120°F (1 - 49°C)
20 - 120 psi (138 - 862 kPA)
20 - 90 psi (138 - 621 kPA)
24V/50-60 Hz, 45 Watts
Influent Challenge
Maximum Permissible
Concentration
Product water
mg/L
Concentration mg/L
0.050 + 10%
0.050 + 10%
0.050 + 10%
0.050 + 10%
Minimum
Reduction
0.010
95.9%
0.010
95.9%
0.010
95.9%
0.010
95.9%
Date
Date
Performance
Data Sheet
Culligan Gold
Arsenic 10"
Average
Reduction
98.7%
98.7%
98.7%
98.7%
01021568
18

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gold arsenic 10"Gold arsenic 12"Gold arsenic 14"

Table of Contents