NOTICE: This system is intended for use on potable water supplies or disinfected water containing Culligan Water cysts. Do not use where water is microbiologically unsafe or with water of unknown quality without Tower™ adequate disinfection before or after the system. Systems certified for cyst reduction may be used CWT35ST.3.0...
Thank you for choosing a Culligan Water Tower™ drinking water system. Your new system is designed to bring you years of healthful, deliciously crystal-clear Culligan faucet installed on your sink, it’s like getting bottled water straight from your kitchen tap.
Application Guidelines The Culligan Water Tower drinking water system is designed for use on potable water supplies meet- ing the guidelines outlined in Table 1. The system should be installed on your home’s cold water line.
Chromium, Lead, Radium 226/228*, Selenium, Total Dissolved Solids, Trivalent Chromium, Cysts, and Turbidity The Culligan Water Tower™ conforms to NSF/ANSI 58 for pentavalent arsenic reduction. See per- formance data sheet and arsenic facts section for an explanation of reduction performance.
This Owner’s Guide provides visual assembly reference only (Figure 2). Since specialized skills are Installation required in the assembly of the drinking water system, we recommend that you contact your local independently operated Culligan Component Location Product Water Faucet Faucet may be located in any convenient location. Make sure underside of location is free of obstruc- tion.
Cartridge Replacement Culligan recommends that you have your Culligan Water Tower drinking water system serviced by your local Culligan Man™. You can rely on his or her experience and expertise to keep your system in top operating condition. Servicing your...
If you wish to service your system, the filters are available from your Culligan dealer. To locate your nearest Culligan dealer, call (800) 285-5442, or visit our website at www.culligan.com. See the Parts List at the end of this section for replacement numbers.
Page 11
Note: Use hand pump to avoid damaging tank. Verify product water faucet is open before pro - ceeding. Use caution when working with/inside enclosure. Wiring therein connects monitor com - ponents. If wires, circuit board, or connections are damaged and/or wetted, monitor will not function.
Page 12
12. Place a small amount of O-ring lubricant on surface of filter housing O-ring. Install O-ring into housing. TO SANITIZE THE SYSTEM: Complete Steps 13-33. TO INSTALL FILTERS: Complete Steps 20-33. 13. Mix sanitizing solution of 1.5 ml (1/3 teaspoon) of household bleach and 3.8 L (1 gallon) of clean, potable water in the bucket.
Page 13
Note: Tighten filter housings by hand only. Do not use tools as they will over-tighten and dam - age housings. 15. Slowly open source water supply valve. 16. Close product water faucet as soon as water begins to flow from spout. 17.
Page 14
TO RE-SET MONITOR or TO CHANGE BATTERY: Perform Steps 24-27 Refer to Figure 6 for component location. Use caution when working inside enclosure. Wiring therein connects monitor components. If wires, circuit board, or connections are damaged and/or wetted, monitor will not function. Connect battery to monitor after system has been in production mode for at least 5 minutes.
Page 15
30. Open product water faucet. Let water flow until all air has been expelled from the system. 31. Close product water faucet. Wait 30 minutes, check connections for leaks, and correct if neces- sary. Icemaker/Extra point of use: Check lines for leaks. 32.
Replace pre-filter cartridge(s) Empty water from storage tank (product water faucet must remain open while adjusting pressure) and adjust pressure to 55 kPa (8 psig) Contact your Culligan Dealer ® Replace flow control (Item 6) in parts list and contact your...
Culligan Water Tower™ Service Log Service Log Model Serial No. Date Installed For Service Call Culligan at: Cartridge(s) Changed Activated Activated Date Sediment Pre-Carbon Post-Carbon Serviced Filter Filter Membrane Filter Sanitized...
Have the treated water tested for arsenic to check if the system is working properly. The RO component of the Culligan Water Tower CWT35ST3.0 must be replaced every 3-5 years to ensure the system will continue to remove pentavalent arsenic. The component identification and...
Any part found defective within the terms of this warranty will be repaired or replaced by the dealer. If any part is found defective, Culligan also reserves the right to replace the drinking water appliance with a comparable Culligan drinking water system of equal or greater quality. You pay only freight for repaired or replaced parts from our factory and local dealer charges, including but not limited to labor charges, travel and transportation expenses and handling fees.
Page 23
This page contains materials and DCO information. IT DOES NOT PRINT AS PART OF THE DOCUMENT! Materials & Description: Good Water Machine Owners Guide Size: 11” x 17” Booklet folded to 8.5” x 11” Color: Black; 2 Sided Stock: 20# White Other: Saddle Stitch (2 Staples) Booklet 3 Hole Drill (Standard)
Need help?
Do you have a question about the Drinking Water System and is the answer not in the manual?
Questions and answers