This display will be followed (2) seconds later by Figure 61.
The "+" or "-" keys are used to toggle the display between "yes" or "NO"
(the default is "NO"). A "yes" response will indicate that the control is to
perform a regeneration on specific days of the week. If this feature is not
desired, set the display to "NO" press the Status key and move on to step
#8. If the feature is desired, set the display to "yes" and move to program
step 8A.
a.
Specific Day(s) of Week Regeneration* - (Only for single sys-
tems that are set with DIP switch 8 OFF and without a meter or
Aqua-Sensor device connected as described in the previous
NOTE).
The display will show "day" and the REGEN icon (Figure 62) for
two seconds followed by "SUN N" (Figure 63). The "+" and "-"
keys are used to toggle between a "Y" or "N" in the display next
to the abbreviated day. To allow a regeneration to occur on
the day shown, toggle the display to "Y". If no regeneration is
desired, the display should indicate "N".
To advance to the next day in the program sequence, use
the Regeneration key and repeat the steps from the previous
paragraph for each day of the week. When complete, press the
Status key once to advance to the next step.
b.
Current Day of the Week* - If any of the days from step 9A.
were set to "Y", the display will show "SetdAY" (Figure 64) fol-
lowed by "SUN" (Figure 65). Use the "+" or "-" keys to scroll the
display to the current day of the week.
If all of the days were set to "N" then "days 03" will appear as
shown in
lished as an interval schedule instead of on selected days.
Press the Status key to save the setting and advance to the next
programming step.
NOTE
1. If any day of the week is set to "Y", then the step 9 display "days 03" will no longer appear when
scrolling, in the future, through the programming menu. To return to a schedule based on an interval
of a specific number of days, chose "NO" after the "dAYoWK" text is displayed.
NOTE
2. If a DIP switch is changed anytime after the control has been programmed to regenerate on a spe-
cific day, all settings will revert back to default; specific days to regenerate and current day will require
reprogramming.
9.
Batch Set Point* - (Only active when a flow meter is attached)
This portion of the program established how many units (e.g. gallons or
liters) of water can be treated prior to regeneration being initiated. The
amount to be inputted shall be dependent on the setting of DIP switch 2
(multiplied by 10 or 100).
The display will show the "REGEN" icon and "bAtch" (Figure 66) followed
(2) seconds later by the "X10" or "X100" icon and "000087" (the default
setting) in the display (Figure 67). To adjust the gallons setting, use the
"-" or "+" keys to scroll to the desired number. (Adjustable from 0 to
999999). Pressing the "-" or "+" keys for 3 seconds or more will cause
the digits to scroll rapidly and at intervals greater than one at a time.
Pressing the Status key will save the setting and move to the next pro-
gramming step.
38
Culligan® CSM Series Filters
Figure 58
and the regeneration interval will be estab-
Figure 61.
Figure 62.
Figure 63.
Figure 64.
Figure 65.
Figure 66.
Figure 67.
38
Cat. No. 01016449

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents