Specifications

Pressure Range:
30–125 psi (2.1–8.6 bar)
Temperature Range:
40–100°F (4.4– 37.7°C)
Parts Included
• filter housing assembly with built-in mounting bracket and quick-connect fittings
inch (10 mm) tubing
3
8
• (2) quick-connect elbows
• SW-5
housing wrench
A
• D-20
cartridge
A
Tools Required
screwdriver
file
pencil
pipe cutter or hacksaw
Precautions
Do not use with water that is microbiologically unsafe or of unknown
quality without adequate disinfection before or after the system. Systems certified for
cyst reduction may be used on disinfected waters that may contain filterable cysts.
Filter must be protected against freezing, which can cause cracking of the
filter and water leakage.
The rubber O-ring provides the water-tight seal between the cap and the
bottom of the housing. It is important that the O-ring be properly seated in the groove
below the threads of the housing or a water leak could occur.
Because of the product's limited service life and to prevent costly repairs or
possible water damage, we strongly recommend that the bottom of all plastic housings
be replaced every ten years. If the bottom of your housing has been in use for longer
than this period, it should be replaced immediately. Date the bottom of any new or
replacement housing to indicate the next recommended replacement date.
NOTE:
• For cold water use only.
• Make certain that installation complies with all state and local laws and regulations.
• The contaminants or other substances removed or reduced by the selected cartridge
are not necessarily in your water. Ask your local water municipality for a copy of
their water analysis, or have your private well tested by a reputable water testing
lab.
• After prolonged periods of non-use (such as during a vacation) it is recommended
that the system be flushed thoroughly. Let water run for 5–6 minutes before using.
• The filter cartridge used with this system has a limited service life. Changes in
taste, odor, color, and/or flow of the water being filtered indicate that the cartridge
should be replaced.
Optional Materials
faucet (FCT-1) for use with D-40
cartridge
Technical Support: 1-800-721-9243 (M-F 8:00 am - 4:30 pm CST)
• Some harmless bacteria may attack cellulose media cartridges (such as the D-10).
If your cartridge seems to disintegrate or develops a musty or moldy odor, switch to
a synthetic media cartridge or call Technical Support.
The US-600
NSF/ANSI Standard 42 for the reduction of Aesthetic Chlorine Taste and Odor.
Systems tested and certified by NSF International with cartridges D-10, D-20
and D-40
Installation
NOTE:
• For standard under-sink installation on
PVC pipe).
• Please read all instructions and precautions before installing and using your
US-600A under-sink filter.
• Install filter cartridge in filter housing before proceeding with installation (see Filter
filter
A
Cartridge Replacement on p. 2).
• Numbered diagrams correspond with numbered steps.
1. (A) Turn off cold water supply and open nearest faucet to release pressure in pipes
before starting installation. Place a tray or towels under the cold water line to catch
excess water. (B) Select location under sink where filter is to be mounted. Use
mounting bracket as a template to mark screw locations. Mount filter in marked
location using mounting bracket.
NOTE: (C) Allow 1
1
cartridge changes.
2. Using a pipe cutter or hacksaw, remove a 3-inch (76 mm) section of pipe (A) from
the
inch (10 mm) cold water line. Deburr ends of remaining pipe with a file. (B)
3
8
Push a quick-connect elbow onto each end of remaining cold water line. Be sure to
push elbow onto pipe until you hit a hard stop.
3. Determine the lengths of tubing needed to connect the inlet and outlet sides of
filter to the quick-connect fittings on the cold water line. Measure tubing short
enough to prevent kinking. Cut the tubing squarely between the closest set of
black guide arrows. Assemble as shown in Figure 3 on page 2, inserting tubing into
appropriate inlet or outlet quick-connect fitting until it stops (inlet and outlet are
marked "IN" and "OUT" on cap).
NOTE: When cut between a set of black guide arrows, the tubing should be pushed
1
A
C
with D-20
has been tested and certified by NSF International against
A
A
. See Performance Data Sheet, in manual, for specific claims.
A
inch (10 mm) cold water line (copper or
3
8
inches (33 mm) clearance below housing to enable filter
2
2
B
A
1
"
1
2
, D-30
,
A
A
B
01020691 REV A 06/09

Advertisement

Table of Contents
loading

Summary of Contents for Culligan US-600A

  • Page 1: Specifications

    • SW-5 housing wrench • Please read all instructions and precautions before installing and using your • D-20 cartridge US-600A under-sink filter. Tools Required Optional Materials • Install filter cartridge in filter housing before proceeding with installation (see Filter •...
  • Page 2: Filter Cartridge Replacement

    Replacement Parts 1 01020827 OR-233 O-ring 2 01020823 SW-5 housing wrench not shown For replacement parts, contact your nearest retailer or call Culligan Consumer Services at 1-888-777-7962. Maintenance Contact your area retailer or local water treatment professional for replacement cartridge pricing.
  • Page 3: Troubleshooting

    Filter Cartridge Selection Guide D-20 Cartridge Max. Select the right cartridge for Permissible D-10 D-20 D-30 D-40 † your water needs Influent Challenge Product Water Reduction Minimum Average Substance Concentration Concentration Requirements Reduction Concentration sediment • • Standard 42 Aesthetic Effects bad taste &...
  • Page 4: Warranty

    Turbidity = 5 NTU Max. Culligan’s opinion is defective, unless: (1) any part of the system has been subjected to any type of tamper- = 7.5 ± 1 ing, alteration, or improper use after delivery, or (2) any part of the system has been repaired by anyone not Temperature = 68°F ±...
  • Page 5: Instalación

    Especificaciones Margen de Presión: 30-125 psi/2,1-8,6 bar El US-600A ha sido probado y certificado con el D-20 por el NSF internacional con el Margen de Temperatura: 40-100°F/4,4-37,7°C estándar 42 de NSF/ANSI para la reducción del gusto y del olor estéticos de la clorina.
  • Page 6: Piezas De Repuesto

    Por piezas de reemplazo, póngase en contacto con el minorista más cerca a usted o llame gratis al departamento de servicios Culligan 1-888-777-7962. Ajustes y Reparaciones Contacte al minorista más cercano o un profesional para el tratamiento de agua por el precio del los...
  • Page 7 Diagrama para Seleccionar Caudal = 1 gpm (3.78 Lpm) Capacidad = 250 galones (946 L) ó 3 meses Seleccione el cartucho filtrante a Cartucho Filtrante D-20 pro pi ado para las necesidades D-10 D-20 D-30 D-40 † de su agua Concentratción Sedimento •...
  • Page 8 Culligan reemplazará cartucho filtrante cualquier pieza la cual en la opinión de Culligan es defectuosa, al menos que: (1) cualquier pieza del sistema Presión = 30–125 psi (2.1-8.6 bar) haya sido sujetado a cualquier clase de interferencia, alteración, o uso inapropiado después de entrega, o (2)