Page 2
Products manufactured and marketed by Culligan International Company (Culligan) and its affiliates are protected by patents issued or pending in the United States and other countries. Culligan reserves the right to change the specifications referred to in this literature at any time, without prior notice. Culligan, Culligan Gold Series, Cullar, Filtr-Cleer, Cullneu, Cullsan, Cul-Cleer, Accusoft, Tripl-Hull, Culcite, Culligan Man and www.culligan.com are trademarks of Culligan Interna-...
Installation, Operating Instructions and Parts List CULLIGAN GOLD SERIES AUTOMATIC WATER FILTERS with Cullar, Cullneu or Cullsan Media MODELS FROM 2001 Table of Contents Page Introduction ............... 2 Specifications ............3 Preparation ............... 4 Installation ..............6 Settings ..............11 Programming ............
Introduction The Culligan Gold Series water filters are tested and validated by WQA against WQA S-200. The Culligan Gold Series Filtr-Cleer filter has been tested and validated by WQA against S- ® 200 for Class IV (≥15µm to <30µm) particulate reduction as verified and substantiated by test data.
Specifications Culligan Gold Series Water Filters with Cullar, Cullneu, or Cullsan Media 9-INCH 12-INCH GENERAL Mineral Tank Size 9x45 in. 12x45 in. Control Hi-Flo Power Valve Hi-Flo Power Valve Timer Electronic Electronic Temperature Limits 33-120°F 33-120°F Water Pressure Limits 20-120 psi...
APPLICATION Correct application is directly associated with the performance and life expectancy of any water conditioner. It is important, therefore, to understand how your Culligan Water Filter functions, and to know its capabilities and ®...
Page 7
COMPONENT DESCRIPTION The water conditioner is shipped from the factory in several cartons. Remove all components from their cartons and inspect them before starting installation. Control Valve Assembly - Includes the 5-cycle regeneration control valve and the Accusoft Microprocessor. Small ®...
Fill the tank with water and allow the media to soak for 24-48 hours. The water level in the tank will decrease as the media soaks up water. Add water to the tank to keep the media submerged so all of the media gets saturated. CULLIGAN GOLD SERIES WATER FILTERS...
Page 9
CULLNEU FILTERS Cullneu filters are shipped with 2 bags of Cullneu with 9" filters and 3 bags of Cullneu with 12" filters. • Cover the top of the manifold with a clean rag. • Place a wide mouth funnel in the tank opening. The Cullneu media should be added with no water in the tank. •...
Page 10
PLUMBING CONNECTIONS Shipped with each filter is a Culligan bypass valve, which is used to connect the softener to the plumbing system. The bypass valve can be directly plumbed into the system, or can be connected with the optional sweat connection kit, P/N 01-0107-83.
Page 11
BYPASS VALVE INSTALLATION The bypass valve connects directly to the control valve with a pair of couplings and two assembly pins (Figure 5). Lubricate all o-rings on the couplings with silicone lubricant. NOTICE: The bypass stem can only be removed from valve on the bypass side (red knob). The bypass valve is designed so that it can be flipped over, with the bypass (red) knob on the left side of the valve.
Settings The Culligan Automatic Water Filter is designed to perform efficiently on a wide range of water supplies. In order to ensure proper operation of the filter, and before initiating the initial recharge and putting the unit into service, the following settings need to be made.
1 and 15 minutes using the up and down arrows. A number “6” will appear at the bottom of the display while in this mode. L to increase or Press M to decrease CULLIGAN GOLD SERIES WATER FILTERS...
Page 15
Press status again to display the Fast Rinse Time in minutes. The setting can be adjusted from 5-30 minutes by using the up and down arrows. A number “7” will appear at the bottom of the display while in this mode. L to increase or Press M to decrease...
Manual Cycling The Culligan microprocessor can be indexed through the various regeneration stages. For all steps, the cycle numbers do not appear, or change, until the motor stops. Press the status button to move past steps 1-10 until the display is blank. Push the up arrow. The number “11” icon will light up.
Service Check The service check mode allows one to view the instantaneous flow rate, the days since the last regeneration, the total number of regenerations, the regenerations in the past fourteen days, and the gallons remaining. To enter the service check mode, follow these steps: Press the status key to move past steps 1-10 until the display is blank.
DISPLAY There are two display modes on the Culligan microprocessor. As shipped from the factory, the display of the board is initially set to turn off if there has been no keyboard activity after a 1 minute period. Touching any key will relight the display.
Operation, Care and Maintenance CULLNEU FILTER REFILLING As water passes through a Cullneu water filter, the media slowly dissolvers and neutralizes the water. The rate at which the Cullneu media dissolves depends on a number of factors such as temperature, flow rate and pH. Because these factors are so variable, it is often difficult to determine how often new Cullneu media should be added.
Page 22
Item Part Number Description Qty. 01-0112-82 Tank Replacement, 9", Empty 01-0112-83 Tank Replacement, 12", Empty 01-0098-47 Top Strainer - Fine Slot 01-0111-95 Top Strainer - Wide Slot 01-0090-99 O-Ring, Manifold 01-0096-15 Outlet Manifold 00-4704-29 O-Ring, Plug 01-0100-46 Plug CULLIGAN GOLD SERIES WATER FILTERS...