10) Parameter of hard limit function(16 in total)

Para.
Parameter definition
Mark
#400
enable X-- limit
#401
enable Y-- limit
#402
Enable Z-- limit
#403
enable A-- limit
#404
enable X++ limit
#405
enable Y++ limit
#406
enable Z++ limit
#407
enable A++ limit
#408
Electric level X-- limit
#409
Electric level Y-- limit
#410
Electric level Z-- limit
#411
Electric level A-- limit
#412
Electric level X++ limit
#413
Electric level Y++ limit
#414
Electric level Z++ limit
#415
Electric level A++ limit

11) Parameter of hard and soft limit function (9 in total)

Para.
Parameter definition
Mark
#374
enable Soft Limit
#375
value of X-- Soft Limit
#376
value of Y-- Soft Limit
#377
value of Z-- Soft Limit
#378
value of A-- Soft Limit
#379
value of X++ Soft Limit
#380
value of ++ Soft Limit
#381
value of Z++ Soft Limit
#382
value of A++ Soft Limit

12 ) System parameter(11 in total)

Para.
Parameter definition
Mark
Interface response speed
#2
while processing
#88
Enable of beep
#114
Enable of Cont and Step Mode
#115
Coordinate unit selection
#120
U disk partition type
#218
Cycle Start key mode selection
#249
Time of the Logo Display
#495
circle of interpolation
#250
enable of draw tool road
#253
mode of draw
#495
Interpolation period
Default
Parameter
Parameter
value
Unit
Scope
1
BOOL
1
BOOL
1
BOOL
1
BOOL
1
BOOL
1
BOOL
1
BOOL
1
BOOL
0
BOOL
0
BOOL
0
BOOL
0
BOOL
0
BOOL
0
BOOL
0
BOOL
0
BOOL
Default
Parameter
Parameter
value
Unit
Scope
0
BOOL
-400
BOOL
-2000~0
-400
BOOL
-2000~0
-400
BOOL
-2000~0
-400
BOOL
-2000~0
400
BOOL
0~2000
400
BOOL
0~2000
400
BOOL
0~2000
400
BOOL
0~2000
Default
Parameter
Parameter
value
Unit
Scope
400
BOOL
400-10000
1
BOOL
0
BOOL
0
BOOL
0
BOOL
0
BOOL
2
s
0.1-10
0.002
s
0.002-0.01
1
BOOL
0
BOOL
0.005
s
0.002~0.01
Page -40
Notes
1/0
0:Disable 1:Enable
1/0
0:Disable 1:Enable
1/0
0:Disable 1:Enable
1/0
0:Disable 1:Enable
1/0
0:Disable 1:Enable
1/0
0:Disable 1:Enable
1/0
0:Disable 1:Enable
1/0
0:Disable 1:Enable
1/0
1: High; 0:Low
1/0
1: High; 0:Low
1/0
1: High; 0:Low
1/0
1: High; 0:Low
1/0
1: High; 0:Low
1/0
1: High; 0:Low
1/0
1: High; 0:Low
1/0
1: High; 0:Low
Notes
1/0
0:Disable, 1:Enable
The set value will trigger the limit signal.
The limit values refer to the machine
coordinates, not the work piece coordi-
nate.
The set value will trigger the limit signal.
The limit values refer to the machine
coordinates, not the work piece coordi-
nate.
Notes
Note: For general G-code file, the
parameter can be set as 400. If the file
has many small segments, adjust the
parameter to be larger.
1/0
0:Disable,1:Enable
1/0
0:Enable,1:Disable
1/0
0:Metric; 1:Imperical
1/0
0: partitions; 1: no partitions
1/0
0: pause&start; 1: restart
circle of interpolation
1/0
0:disable 1: enable
1/0
0:statue mode 1:line mode
DM500 User's Manual