5.4.1.2
Floating Tool Sensor
If use the floating tool sensor,means the X and Y axis positon of the tool sensor is not fixed.We need to
move the cutter above the tool sensor manually.
The working Piece
Condition:
• Controller is in READY status;
• The screen go to "Main page"
Operation
1) Set the Index No.68 value to 1;(The Parameter 68 value is 1,means Probe function enabled);
2) By Index No.70,Set the probe port effective electric level.Normally Open is default;
3) Set the probe way.Set Index No. 71 value to 0.(The parameter 71 value is 0,means Initial tool's position
is current position.)
4) Go to Parameter 69 and type in the thickness of the tool sensor.You should know it in advance.
5) Move the cutter above the tool sensor manually;
6) Press the key
Move the cutter above the tool sensor manually
2
3
Tool
The thickness of tool sensor
Sensor
The machine Table
The probe processing of floating tool sensor
and
,the press
Probe
Page -27
The origin position of the cutter
1
to probe.
DM500 User's Manual