cRIO-905x Startup Options
You can configure the following cRIO-905x startup options.
Startup Option
Force Safe Mode Rebooting the cRIO-905x with this setting on starts the cRIO-905x
Enable Console
Out
Disable RT
Startup App
Disable FPGA
Startup App
Enable Secure
Shell (SSH)
Logins
LabVIEW Project
Access
Table 1. cRIO-905x Startup Options
without launching LabVIEW Real-Time or any startup applications. In
safe mode, the cRIO-905x launches only the services necessary for
updating configuration and installing software.
Rebooting the cRIO-905x with this setting on redirects the console
output to the USB 2.0 Type-C Device Port with Console Out. You can
use a serial-port terminal program to read the IP address and firmware
version of the cRIO-905x. Make sure that the serial-port terminal
program is configured to the following settings:
115,200 bits per second
Eight data bits
No parity
One stop bit
No flow control
Rebooting the cRIO-905x with this setting on prevents any LabVIEW
startup applications from running.
Rebooting the cRIO-905x with this setting on prevents autoloading of
any FPGA application.
Rebooting the cRIO-905x with this setting on starts sshd on the
cRIO-905x. Starting sshd enables logins over SSH, an encrypted
communication protocol.
Note
Visit
for more information about SSH.
Rebooting the cRIO-905x with this setting on enables you to add the
target to a LabVIEW project.
Description
ni.com/info
and enter the Info Code
NI cRIO-905x User Manual | © National Instruments | 5