Pulse Train Generation; Single Pulse Generation With Start Trigger - National Instruments NI cRIO-905x Series User Manual

Embedded compactrio controller with real-time processor and reconfigurable fpga
Table of Contents

Advertisement

You can specify a pulse width. The pulse width is also measured in terms of a number of
active edges of the Source input. You also can specify the active edge of the Source input
(rising or falling).
The following figure shows a generation of a pulse with a pulse delay of four and a pulse
width of three (using the rising edge of Source).

Single Pulse Generation with Start Trigger

The counter can output a single pulse in response to one pulse on a hardware Start Trigger
signal. The pulse appears on the Counter n Internal Output signal of the counter.
You can specify a delay from the Start Trigger to the beginning of the pulse. You also can
specify the pulse width. The delay is measured in terms of a number of active edges of the
Source input.
You can specify a pulse width. The pulse width is also measured in terms of a number of
active edges of the Source input. You can also specify the active edge of the Source input
(rising and falling).
The following figure shows a generation of a pulse with a pulse delay of four and a pulse
width of three (using the rising edge of Source).
Figure 76. Single Pulse Generation with Start Trigger

Pulse Train Generation

Refer to the following sections for more information about the cRIO controller pulse train
generation options:
Finite Pulse Train Generation
Retriggerable Pulse or Pulse Train Generation
Continuous Pulse Train Generation
Buffered Pulse Train Generation
88 | ni.com | NI cRIO-905x User Manual
Figure 75. Single Pulse Generation
Counter Armed
SOURCE
OUT
GATE
(Start Trigger)
SOURCE
OUT

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ni crio-9053Ni crio-9054Ni crio-9056Ni crio-9057

Table of Contents