Siemens SINAMICS S120 Operating Instructions Manual page 53

Applications for cabinet modules, liquid-cooled
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

With systematic loading, the total permissible loads specified below apply:
With 45 Bowden cable
bracket
With 60 Bowden cable
bracket
With 90 Bowden cable
bracket
Note
The center of gravity of the cabinet is specified in the dimension drawing. The load carrying
capacity of the hoisting gear must be adequate for the weight specified in the dimension
drawing.
Transport using lifting rails
Inadequately dimensioned lifting rods
Inadequately dimensioned lifting rods are liable to bend or break. The drive could drop off the
crane. This can result in death, serious injury or material damage.
Use suitable lifting rods for transporting. The weight of the cabinet is indicated on the rating
plate.
If the cabinets/transport units are equipped with lifting rails, then proceed as follows:
1. If there are several holes, select which holes to use based on the center of gravity.
2. Push the lifting rods through the holes.
3. Place the sling ropes on the lifting rods so they are close to the cabinet. Secure the ends
of the lifting rods using the splint.
Figure 3-5
4. To lift the transport unit, use single sling ropes or two ropes with a cross stitch. Attach the
crane rope to the lifting rods so it is close to the cabinet.
5. Lift the cabinet. Avoid shifting the center of gravity or distorting or damaging the cabinet.
When suspended, the cabinet must be parallel to the ground.
Siemens Drives & PLCs
Applications for Cabinet Modules, liquid cooled
Operating Instructions, 04/2015, A5E35974555A
4800 N
6400 N
13600 N
WARNING
Securing the lifting rods
Preparations for use
3.3 Transport
53