ETC Installation Guide
ColorSource Linear v1.7
Safety
Read the entire manual before using this equipment.
CAUTION: • Risk of eye injury. Do not stare directly into the light.
WARNING:
Environment
The ColorSource Linear operates in ambient temperatures of 0°C–40°C and
comes with a variable-speed fan.
Note: The ColorSource Linear is for indoor use only.
Note: • Maximum recommended ambient operating
ColorSource Linear v1.7
• Do not operate in proximity to flammable materials.
Disconnect the fixture from power and DMX and allow
it to cool before performing any cleaning and
maintenance.
temperature: Ta = 40°C (104°F)
• Maximum anticipated external surface temperature
at 40°C ambient: Tmax = 80°C (176°F)
• External temperatures after 5 minutes of full-
brightness operation at 25°C (77°F) ambient:
36°C (97°F)
• External Temperature (steady state achieved) at
25°C (77°F): 48°C (118°F)