12.7 System
CL408e/412e
Printer
M-8485Se/90Se/60Se/59Se

12.7 ESC+EP Print End Position

Print End Position
ESC
HEX Code
<1B>
16
Default Value
NIL
Valid Range &
When Power is Switched Off
Terms of
Valid Range within Items
Command
Valid Range between Items
[Function]
To specify label stop position at the sensor invalid mode
[Format]
<EP>
[Coding Example]
<A>
<A1>14240832
<Z>
<A>
<V>100<H>200<P>2<L>0202<XM>ABCD
<Q>2
<EP>
<Z>
e.g.)
1424(dot)
ABCD
[Supplementary Explanation]
1 By using sensor invalid mode.
2. Specify as a set with Label Size Specification <A1>.
3. When Label Size Specification <A1> is specified at Format Register Specification <YS>, Form Overlay Register Specification <&S>, when
each Format Re-Call Specification <YR>, Form Overlay Re-Call Specification <&R> is specified, please specify the Print End Position
Specification <EP>.
M-8400RVe
CL608e/612e
M-84Pro-2/3/6
LC408e/412e
EP
Parameter
<45>
<50>
NIL
16
16
The set parameter is not maintained
The set parameter becomes invalid
The set parameter becomes invalid
Stop position when <EP>
is not specified
Stop position when <EP>
is not specified
M-5900RVe
M-10e
ESC+EP
Start Position
1
1
80mm×100m
m
label
( )の値は12ドット/mm
[ ]の値は24ドット/mm
80mm
640dot
( 960dot)
【1920dot】
104mm
832dot
(1248dot)
【2496dot】
Value of( )is 12dot/mm
Value of【 】is 24dot/mm
210
100mm
800dot
(1200dot)
【2400dot】
178mm
1424dot
(2136dot)
【4272dot】

Hide quick links: