9.14 Barcode
CL408e/412e
Printer
M-8485Se/90Se/60Se/59Se
9.14 ESC+BL UPC-A Barcode (Without
UPC-A Barcode (Without HRI)
HRI)
ESC
HEX Code
<1B>
16
Default Value
NIL
Valid Range &
When Power is Switched Off
Terms of
Valid Range within Items
Command
Valid Range between Items
[Function]
Set the height of character barcode of the first digit and the last digit to the same height of the guard bar.
[Format]
<BL>abbcccn~n
●Parameter
a [Barcode type]
b [Narrow bar]
c [Height of Barcode]
n [Print data]
[Coding Example]
Font type:
<A>
<H>100<V>100<BL>H0312001234567890
<Q>2
<Z>
[Supplementary Explanation]
1. This command supports UPC-A only. When barcode type is specified other than "H", command error occurs.
2. Setting of Guard bar, HRI and ratio is described as follows.
Guard bar
Available
3. When the parameter value exceeds the range, operation is not supported.
4. When printing UPC-A with <D>, all character barcodes have the same height. When <BL> is uses, the height of the character
barcode of the start digit and the last digit have the same height of the guard bar.
Guide bar
Character barcode
First digit
UPC-A specifying <D>
M-8400RVe
CL608e/612e
M-84Pro-2/3/6
BL
Parameter
<42>
<4C>
aaabbcccn~n
16
16
The set parameter is not maintained
The set parameter becomes invalid
The set parameter becomes invalid
= H
: UPC-A(Fixed 'H')
= Valid Range
: 01 to 12 dots
= Valid Range
: 001 to 999 dots
= Data
: 11 fixed digits
UPC-A, Narrow bar width:03, Barcode height:120, Print data:
HRI
Ratio
Nil
Fix
Guard bar
Character barcode
Last digit
M-5900RVe
M-10e
LC408e/412e
ESC+BL
Guard bar
Character barcode
First digit
UPC-A specifying <BL>
116
01234567890
Guard bar
Character barcode
Last digit

Hide quick links: