KPA Ku-Band Indoor Solid-State Power Amplifier
Appendix C
Command
Arguments for
Parameter Type
(Instr Code and
Command or
Qualifier)
Response to Query
Remote Address
SPA=
4 byte,
numerical
Set RTC Time
TIM=
6 bytes,
numerical
Temperature
N/A
4 bytes
Description of Arguments
(Note that all arguments are ASCII numeric codes, i.e., ASCII codes between 48 and 57)
Command or Query.
Set Physical Address-between 0001 to 9999.
Resolution 0001
Example: SPA=0412
Command or Query.
A command in the form hhmmss, indicating the time from midnight, where hh = hours, between
00 and 23; mm = minutes, between 00 and 59, and ss = seconds, between 00 and 59
Example: TIM=231259 would be 23 hours, 12 minutes and 59 seconds from midnight.
Query Only.
Returns the temperatures of the heat sink in the form of a sign byte followed by 3 bytes for the
temperature.
Example: TMP=+26.0
C–16
Revision 1
MN/KPA.IOM
Query
Response to Query
(Instr Code and
(Target to controller)
Qualifier)
SPA?
SPA=xxxx
(same format as
command arguments)
TIM?
TIM=xxxxxx
(same format as
command arguments)
TMP?
TMP=sxxx
(see Description of
Arguments)