Basic system includes:
 Capacity for up to 250 addressable IDNet points, up to
127 VESDA Air Aspiration Systems interface points,
and up to 254 addressable notification appliances with
up to 2000 points of Annunciation; and up to 20
internal and external card addresses
 Color-coded operator interface with membrane keypad
includes 2 x 40 Super-twist LCD display, 3 programmable
control keys and 6 programmable LEDs
 CPU assembly includes dedicated compact flash memory
for on-site system information storage and convenient
Ethernet service port access
Includes an Enhanced System Supply (ESS) that
provides power and battery charging (6 A output):
 Dual 3 A on-board IDNAC SLCs (signaling line circuit)
 IDNAC SLC provides a constant 29 VDC source voltage
during alarm, even during battery operation, allowing
strobes to operate at higher voltage with lower current and
ensuring a consistent current draw and voltage drop
margin under primary and secondary power
 Efficiencies include lower strobe currents, wiring
distances up to 2 to 3 times farther than with conventional
notification, support for more appliances per IDNAC
SLC, ability to use smaller gauge wiring
 IDNAC SLCs are compatible with both TrueAlert ES
and TrueAlert addressable notification appliances, and
remote 4009 IDNAC Repeaters to extend power and
wiring distance even farther and extends supervisory
capacity by up to 139 additional unit loads or 3 A
 Addressable point control is provided by on-board IDNet
2 dual loop SLCs that provide two electrically isolated
channels that support TrueAlarm analog sensors and
IDNet communications monitoring and control points
with an electrically isolated output channel allowing use
with either shielded or unshielded, twisted or untwisted
single pair wiring; and providing dual short circuit
isolating output loops
 Battery charger for up to 110 Ah batteries (UL) or up to
50 Ah batteries (ULC) (33 Ah max in control panel
cabinet)
 2 A programmable function auxiliary output
 Remote annunciator module support via RUI (Remote
Unit Interface) communications port, supports either Class
B or Class A operation
 48 LED panel mount annunciation provides 40 Red and 8
Yellow pluggable LEDs (select models, meets ULC
requirements), optional LED kits are available to change
individual LED color to Green or Blue to meet specific
site requirements
Optional ESS mounted modules, door mounted
modules, and other options include:
 City Connect (with or without disconnect switches)
 Alarm Relay Module
 TrueInsight Remote Gateway
 Battery brackets for seismic area protection (see page 2)
Addressable Fire Detection and Control
Basic Panel Modules and Accessories
1-Bay Cabinet
4010ES Panel Type Reference
Optional block space modules include:
 Fire Alarm Physical Bridge and Network Interface Cards
for Peer-to-Peer fire alarm network communications,
supports either Class B or Class X operation
 Building Network Interface Module (BNIC), SafeLINC
Internet Interface, and BACpac Ethernet Portal
 Dual Class A IDNAC Isolator (DCAI)
 Dual RS-232 Module (for printer, PC annunciator or third
party interface)
 VESDA Air Aspiration High Level Interface
 Serial DACT
 8 Zone IDC Modules Class A or B
 4 Point Auxiliary Relay Module
Compatible with Simplex
 4098-9757 QuickConnect2 and legacy 4098-9710
QuickConnect TrueAlarm smoke sensors
 4003EC Small Voice Panels
 4081 Series, 110 Ah Battery Chargers
 4100-7400 Series Graphic Annunciators
 4190 Series PC Annunciator, 4190 Series Fiber
Modems and Physical Bridges
 4606-9102 Remote LCD Annunciator, 4100-9400
Series Remote InfoAlarm Command Centers, and 4602
Series Status Command Units (SCU) and Remote
Command Units (RCU) Annunciators
 IP communicator compatibility
* See page 6 for additional listing information. This product has been approved by the
California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health
and Safety Code. See CSFM Listing 7165-0026:0369 for allowable values and/or
conditions concerning material presented in this document. NYC Fire Dept COA #6193.
Additional listings may be applicable; contact your local Simplex product supplier for the
latest status. Listings and approvals under Simplex Time Recorder Co. are the property of
Tyco Fire Protection Products.
Fire Control Panels
1-Bay Cabinet with
LED Annunciation
®
remotely located:
S4010-0011-5 11/2015

Advertisement

loading

Summary of Contents for Simplex 4010ES

  • Page 1  TrueInsight Remote Gateway Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of  Battery brackets for seismic area protection (see page 2) Tyco Fire Protection Products.
  • Page 2: Mechanical Description

    Panel Hardware 4010ES Agency listings: 4010ES Block Space Option Cards mount to the left of the 4010ES ESS. There are 3 available 4” x 5” blocks  UL 864, Fire Detection and Control (UOJZ), and for mounting 4010ES hardware options.
  • Page 3 Operator Interface Features  Convenient and extensive operator information is Convenient Status Information. With the locking provided using a logical, menu-driven display door closed, the glass window allows viewing of the display, status LEDs, and available operator switches.  Multiple automatic and manual diagnostics for Features include a two-line by 40-character, wide viewing maintenance reduction angle (super-twist) LCD with status LEDs and switches as...
  • Page 4 4098-9754 provides photoelectric and heat sensor data using communicate their identity and status and receive fire alarm a single 4010ES IDNet address. The panel evaluates smoke system control. Additional addressable interface modules activity, heat activity, and their combination, to provide include circuit isolators, conventional IDC zone adapters, TrueSense early detection.
  • Page 5 IDNAC SLC Control of TrueAlert and TrueAlert ES Addressable Notification problem. Using the TrueAlert magnet test allows each appliance Addressable notification appliance communications to individually identify its candela setting and address and to include operation of TrueAlert and TrueAlert ES Visible only briefly operate if desired, and using the TrueAlert ES (V/O, strobe), Audible only (A/O, horn), Audible/Visible (A/V, Appliance Self-Test feature provides detailed performance...
  • Page 6 Master Controller (CPU) Basic Panel Description  4010ES panels with ESS include: The 4010ES Master Controller includes dedicated 2GB compact flash Mass Storage memory for on-site  An Operator Interface, Master Controller with 2 GB system information storage and convenient Ethernet...
  • Page 7 Addressable Device Load Specifications for Battery Standby Supervisory Addressable Channel Loading Reference Device Load Alarm Current Current 1 mA per device in alarm; 2 mA IDNet 2 Communications Channel Output for every 50 Devices 40 mA per activated device LED IDNAC Communications Channel Output for every 50 Appliances 40 mA...
  • Page 8: Miscellaneous Accessories

    62 mA 62 mA Mounts on Front Door Battery Distribution Terminal Block, mounts to side of box, required when battery connection leaves the 4010ES 4100-5128 box (also used in the 4100ES fire alarm control panel) * Refer to data sheet S4100-0063 and contact your local Simplex product representative for more details.
  • Page 9 (Note: Only select 1 control panel) 2. For the option cards to be installed on the 4010ES, write in the Card Address Consumption value in the Card Address Allocation column. 3. Total the Card Address Allocation column (total must not exceed 20).
  • Page 10 S4100-0029 TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. VESDA is a trademark of Xtralis Pty Ltd. NFPA 72 and National Fire Alarm and Signaling Code are trademarks of the National Fire Protection Association (NFPA). ASHRAE and BACnet are trademarks of ASHRAE, American Society of Heating, Refrigeration, and Air Conditioning Engineers.