Simplex TrueAlarm 4100 Series Manual page 7

Fire alarm control and indicating equipment
Table of Contents

Advertisement

Product Selection (Continued)
Audio Amplifiers
(supervisory current is with "switch to battery" selected)
4100/4120-
0251
25 VRMS, 25 W, without Power Supply
25 VRMS, 100 W, with 230 VAC Power
0263
Supply
Audio Equipment Options
4100/4120-
0254
Microphone and Enclosure
0255
Master Phone
0206
Redundant Tone Generator
0215
Phone Riser Terminal Board
Standard Message Set (Custom
0220
Messages are Available)
Annunciation Equipment
4100/4120-
0301
64/64 LED/Switch Controller, Internal
0302
24 Point I/O Graphic Interface, Internal
0431
Eight Red LED Module
0432
16 Red/Yellow LED Module
8/8 Momentary Switch/Yellow LED
0433
Module
8/16, 3 Position Maintained
0434
Switch/Yellow-Yellow LED Module
0435
8/16 Momentary Switch/LED Module
Network Equipment
Model
4120-6014
Modular Network Interface Board
4120-0142
Wired Media Card
4120-0143
Fiber Optic Media Card
Cabinets and Accessories
4100/4120-
2052
Four Unit
2053
Six Unit
2062
Four Unit
2063
Six Unit
2975-9405
Four Unit Beige Cabinet, CE Compliant
2975-9406
Six Unit Beige Cabinet, CE Compliant
2975-9801
Semi-Flush Trim
Remote Mount Options
4100/4120-
4604-9202UK Remote LCD Panel
24 Point Graphic Interface Module,
7401*
Remote
7402*
64/64 LED/Switch Controller, Remote
7403*
32 Point LED Driver Module, Remote
7404*
32 Point Switch Input Module, Remote
0440
Remote Microphone Enclosure
0441
Remote Phone
(2) LPC Approval pending.
(3) Tested by LPC to verify that no detrimental effect occurred to mandatory EN54 functions.
* Refer to Simplex document S4100-0005 for additional information.
Simplex Time Recorder Co.
Description
LPC Status
Description
LPC Status
Description
LPC Status
Description
LPC Status
Description
LPC Status
with Glass Door
with Solid Door
Description
LPC Status
Quantity
(3)
As Required
Quantity
(3)
As Required
N.A.
Quantity
(2)
N.A.
As Required
(2)
Quantity
N.A.
As Required
Quantity
Choose One Per
Cabinet
(2)
Choose One Per
Cabinet
N.A.
As Required
Quantity
One maximum if
required (see page 4)
N.A.
As Required
7
Standby
Alarm
Module Size
36 mA
2.2 A
2" Internal
68 ma
8.75 A
8" Internal
Standby
Alarm
Module Size
3 mA
7 mA
4" Retainer
22 mA
142 mA
45 mA
45 mA
––
Not applicable
Standby
Alarm
Module Size
15 mA
260 mA
2" Internal
34 mA
75 mA
Not applicable
2" Retainer
Standby
Alarm
Module Size
35 mA
35 mA
2" Internal
40 mA
40 mA
N.A.
25 mA
25 mA
Standby
Alarm
Module Size
Not applicable
Standby
Alarm
Module Size
60 mA
200
see p. 4
42 mA +
78 mA +
switch loads*
outputs*
6 1/2" x12 1/4"
(165 x 311 mm)
67 mA +
285 mA fully
switch loads*
loaded*
3 1/4" x 12 1/4"
current is included
(83 x 311 mm)
with control module
3 mA
7 mA
4" Retainer
N.A.
S4100-0025 (EN54) 5/99

Advertisement

Table of Contents
loading

This manual is also suitable for:

Truealarm 4120 series

Table of Contents