6.
How to make RS485 Daisy Chain multiple camera connection with RS485 standard serial port controller:
Note
For RS-232 VISCA control, this unit does not support daisy chain connection for using multiple cameras.
For control details, refer to Operating Instructions of control keyboard/station software.
You need to match the communication baud rate between the camera and the joystick controller.
You cannot use the RS-232 connections and the RS422/485 connection at the same time.
Operating Multiple Cameras Using RS-422/485
Using RS-422 (VISCA), you can connect up to 7 cameras.
Using RS-485 (PELCO), you can connect up to 255 cameras.
Using RS-485 (PELCO), all camera addresses must be set up before the connection. You can set the camera
address by operating OSD menu, or by setting the Dip Switch on the bottom of the camera.
In this case, you can use multiple control keyboards.
The joystick of the remote keyboard controller allows comfortable pan/tilt and zoom operations.

How to make the connection with BOLIN products

Please see the User Guide "BOLIN Camera and Keyboard Controller Connection"
that you can download it at
www.bolintechnology.com