Operation guide | Installation, Operation and Maintenance Manual for PAH 2-12.5 pumps Validity This manual is valid for PAH pumps both non In case the pump delivered is ATEX certified, the ATEX and ATEX certified versions . An ATEX additional ATEX instruction maus also be read .
Page 5
Operation guide | Installation, Operation and Maintenance Manual for PAH 2-12.5 pumps Introduction General The PAH pumps and pump units are manufac- It is important that these instructions are tured by Danfoss A/S, and are sold and marketed always available to the personnel concerned .
Page 6
Operation guide | Installation, Operation and Maintenance Manual for PAH 2-12.5 pumps 1.3 Manufacturer and customer service Your local Danfoss pump distributor can be address: found on our homepage . Danfoss A/S 1.4 Country specific information High Pressure Pumps 1.4.1 United Kingdom...
Page 7
Operation guide | Installation, Operation and Maintenance Manual for PAH 2-12.5 pumps It is always the system builders´ responsibility • Do not try to lift the pump unit manually; that the system design does not cause any kind most of the pumps weigh more than...
Page 8
Operation guide | Installation, Operation and Maintenance Manual for PAH 2-12.5 pumps 3.7 Filtration 3.9 Air bubbles (10µm absolute [β ≥ 5000]) Large bubbles in a pressurised system can result Requirements are specified in appendix 1, Data in damage to piping, equipment and the pump .
Page 9
Operation guide | Installation, Operation and Maintenance Manual for PAH 2-12.5 pumps Pumps which have a weight above 20 kilos (see Wrong lifting: appendix 1, Data sheet) must be handled by using lifting eyes and slings . When lifting the pump unit, one sling must be attached to the electric motor and one sling around the pump .
Page 10
Operation guide | Installation, Operation and Maintenance Manual for PAH 2-12.5 pumps Installation and commissioning 5.1 Important dimensions Physical dimensions and connections of the 5.3 Fluid temperature pump unit are described in appendix 1, Data Before start-up, the fluid and pump housing sheet .
Page 11
Operation guide | Installation, Operation and Maintenance Manual for PAH 2-12.5 pumps 5.6 Pre mounting checklist, based on Danfoss preferred system design Check points Comment OK ? Ensure that the environmental conditions are safe . See Arrival inspection, transportation, handling, lifting and storage, chapter 4 .
Page 12
Operation guide | Installation, Operation and Maintenance Manual for PAH 2-12.5 pumps 5.12 Ensure free flow • Check the temperature switch/controls . The Ensure free flow from relief valve (table 1, item high-pressure pump must stop if tempera- 5 .6, CP 8) . A blocked relief valve can cause ture is above specified set point .
Operation guide | Installation, Operation and Maintenance Manual for PAH 2-12.5 pumps Operation of motor pump unit 6.1 General safety information Drop in flow and/or pressure – may indicate Before inspecting the pump unit, read the Safety wear on one or more parts inside the chapter 2 in this user manual .
Operation guide | Installation, Operation and Maintenance Manual for PAH 2-12.5 pumps Slowly unscrew and remove the bolts and gaskets from the inlet/outlet hoses or pipes, be careful about jets of water . Be aware that the system can be pressurized .
Operation guide | Installation, Operation and Maintenance Manual for PAH 2-12.5 pumps Electrical Troubleshooting and hazard scrapping criteria 8.1 General safety information 8.4 Electrical failure Before inspecting the pump unit, it is necessary If the wiring of the electric motor is incorrect or...
Data sheet PAH 2/4/6.3, PAH 10/12.5, PAH 20/25/32 and PAH 50/63/70/80/100 pumps Below sectional drawing is an example of a PAH pump . 1: Shaft sealing 2: Mounting flange/ housing with bearing 3: Retaining ring 4: Piston/shoe 5: Valve trust plate...
Data sheet PAH 2/4/6.3, PAH 10/12.5, PAH 20/25/32 and PAH 50/63/70/80/100 pumps Flow The flow (Q ) at various pressure (p ) can be At zero pressure the true flow equals the calculated with the following equation: theoretical flow Q (th) –...
Data sheet PAH 2/4/6.3, PAH 10/12.5, PAH 20/25/32 and PAH 50/63/70/80/100 pumps Motor requirements The required motor power can be calculated by using the following equation: n x V x p 600 .000 x η P: Power (kW) M: Torque (Nm) η: Mechanical efficiency...
Data sheet PAH 2/4/6.3, PAH 10/12.5, PAH 20/25/32 and PAH 50/63/70/80/100 pumps Installation See the figure below for instructions on how to mount the pump and connect it to an electric motor or combustion engine . A: Flexible coupling B: Bell housing...
Data sheet PAH 2/4/6.3, PAH 10/12.5, PAH 20/25/32 and PAH 50/63/70/80/100 pumps 7.3 Open-system design Hoses: Always use flexible hoses (5) to minimize Inlet line: vibrations and noise . Dimension the inlet line to obtain mini- Inlet pressure: mum pressure loss (large flow, minimum...
Data sheet PAH 2/4/6.3, PAH 10/12.5, PAH 20/25/32 and PAH 50/63/70/80/100 pumps Closed-system design Hoses: Always use flexible hoses (6) to minimize Inlet line: vibrations and noise . Dimension the inlet line to obtain mini- Inlet pressure: mum pressure loss (large flow, minimum...
Data sheet PAH 2/4/6.3, PAH 10/12.5, PAH 20/25/32 and PAH 50/63/70/80/100 pumps Service Other factors that affect pump performance and Danfoss PAH pumps are designed for long periods of service-free operation to ensure low lifetime include: maintenance and life cycle costs . Provided that the pump is installed and operated according to •...
Install the inlet filter (1) in front of the tank the pump . (2) . Please consult the Danfoss filter data Pressure relief valve: sheet for guidance on how to select the As the Danfoss PAHT pump begins to right filter .
Install the inlet filter (1) in front of the PAHT specifications described in item 4, technical pump (2) . Please consult the Danfoss filter data . data sheet for guidance on how to select Non-return valve (6): the right filter .
The pump is now protected against internal corrosion and frost . corrosion and frost . Service The Danfoss PAHT pumps are designed for long Other factors that affect pump performance and periods of service-free operation to provide lifetime include: customers with low maintenance and life cycle costs .
Electric Motors Motor Manual hoyermotors.com M a n u a l...
Page 44
Inspect the motor at regular intervals, keep it clean and doubled supply frequency. ensure free ventilation air flow, check the condition of shaft Only mount or remove drive components (pulley, coupling, seals and replace if necessary. Both electrical and mechanical 180R9379 | AQ188686503004en-000801 | PAH 2-12.5 } 07.2022...
Page 45
At 60Hz the time will be reduced by app. 20%. Maintenance, repairs and replacement on this type must Data for vertically mounted motors are half of the above only be carried out by qualified specialists. values. 180R9379 | AQ188686503004en-000801 | PAH 2-12.5 } 07.2022...
Page 48
T +86 574 26 28 15 77 · F + 86 574 2628 1573 sweden@hoyermotors.com korea@hoyermotors.com hoyermotors@hoyermotors.cn hoyermotors.com hoyermotors.com hoyermotors.cn Important notice. Text and data in this catalogue are not binding and we reserve the right to implement changes without further notice. 180R9379 | AQ188686503004en-000801 | PAH 2-12.5 } 07.2022...
B - Flexible coupling C - Motor shaft 1 .6 Pump damage 1 .6 . 1 Contact Danfoss sales office for guidelines Instructions on internal elements are available (the internal parts may be damaged) in how to troubleshoot internal pump on www .danfoss .high-pressurepumps .com...
. installed: Start motors simultaneously . 3 .3 Constant torque 3 .3 . 1 Please contact Danfoss High Pressure If the electric motor is too small for the pump, it Pumps sales office . cannot provide sufficient torque .
4 .7 . 1 Check if noise is normal when the pump is Noise frequency changes during soft start-up/ running at operation speed . stop . 4 .7 .2 If noise is abnormal at operation speed, check internal parts (see above) . 180R9379 | AQ188686503004en-000801 | PAH 2-12.5 } 07.2022...
5 .5 . 1 Mount a vibration dampener below the When no dampener is installed below the motor motor/pump . electric motor, vibrations from the motor and pump may be transferred to the frame and the rest of the system/plant . 180R9379 | AQ188686503004en-000801 | PAH 2-12.5 } 07.2022...
. If any scratches or marks can be felt by running a fingernail over the surface, the valve plate is worn . The valve plate on picture 3 is highly damaged . 180R9379 | AQ188686503004en-000801 | PAH 2-12.5 } 07.2022...
To check this, please see item 6 . 1 , picture 3 . If the surface has any marks/scratches, it is worn/damaged and a new one is required . Please contact Danfoss High Pressure Pumps sales office for further infor- mation . 180R9379 | AQ188686503004en-000801 | PAH 2-12.5 } 07.2022...
Page 69
Guideline Trouble shooting guide for PAH, PAHT, PAHT C , PAHT G pumps 180R9379 | AQ188686503004en-000801 | PAH 2-12.5 } 07.2022...
Page 70
Guideline Trouble shooting guide for PAH, PAHT, PAHT C , PAHT G pumps 180R9379 | AQ188686503004en-000801 | PAH 2-12.5 } 07.2022...
Page 71
Guideline Trouble shooting guide for PAH, PAHT, PAHT C , PAHT G pumps 180R9379 | AQ188686503004en-000801 | PAH 2-12.5 } 07.2022...
MAKING MODERN LIVING POSSIBLE Service guide. Right and wrong Right and wrong Trouble shooting guide for water hydraulic systems Trouble shooting guide for water hydraulic systems danfoss.high-pressurepumps.com hpp.danfoss.com...
Page 74
Placing the return filter upstream of the Locate the return filter in the return line Filling system with unfiltered System to be filled via filter final load may damage the pump immediately before the tank water causes damage 180R9379 | AQ188686503004en-000801 | PAH 2-12.5 } 07.2022...
Page 75
Correctly limited quantities of grease Too much grease may develop Starting without water will cause Fill system with water before starting prevent seizing biofilm causing operational failures damage to ensure lubrication and cooling 180R9379 | AQ188686503004en-000801 | PAH 2-12.5 } 07.2022...
Page 76
Insufficient bleeding may cause dam- If the system is not cleaned before Observing the starting procedure will cooling and lubrication age (not applicable to Power Packs) starting, the filter will clog ensure problem-free operation 180R9379 | AQ188686503004en-000801 | PAH 2-12.5 } 07.2022...
Page 77
A blown fuse / or short circuit? Check power supply and fuses and contact Replace filter element electrician Replace filter element Contact serviceman Turn on the tap for water supply Stamp 180R9379 | AQ188686503004en-000801 | PAH 2-12.5 } 07.2022...
Page 78
Is the filter clogged? Check power supply Fill water into the system and fuses and contact Replace filter element Is the filter control electrician light on? Contact serviceman Trace leakage, if any Stamp 180R9379 | AQ188686503004en-000801 | PAH 2-12.5 } 07.2022...