Danfoss 90 Series Service Manual page 41

Hide thumbs Also See for 90 Series:
Table of Contents

Advertisement

Service Manual
Adjustments
Series 90 Pumps
3. Turn the sensor counterclockwise (CCW) 1/2 turn (180°) to establish the nominal gap of 0.71 mm
[0.028 inch].
4. Then turn the sensor clockwise (CW) until the wrench flats on sensor body are positioned at a 22°
angle to the pump shaft center line.
Most open-end wrenches have a 22° handle offset.
5. The final sensor position should be between 1/2 (180°) and 1/4 turn (90°) counterclockwise (CCW)
from the point where the sensor contacts the speed ring.
6. Hold sensor in position with a 1/2 inch hex wrench while tightening the lock nut to 13 N•m [10 lbf•ft].
Cross section view of speed sensor in variable pump
Gap
Speed sensor
Magnetic speed ring
Cylinder block
Positioning speed sensor relative to pump shaft
Shaft centerline
1/2 inch wrench flats
22°
22°
Speed sensor with
Speed sensor with
packard connector
Shaft centerline
1/2 inch wrench flats
22°
22°
Speed sensor with
Speed sensor with
packard connector
520L0818 • Rev 0101 • August 2015
P104 152E
turck connector
turck connector
P104 155E
41