Terminal
Terminal
Block
Number(s)
Signal
TB20
1
Drive Enable (NO)
Motor Thermoguard (NC)
2
3
Normal Stop (NC)
4
External Fault (NC)
5
Input Common
6
7
8
Fault Output (NC)
9
Fault Output (COM)
Fault Output (NO)
10
1
OUT 1
TB21
COM 1
2
3
OUT 2
4
COM 2
5
OUT 3
6
COM 3
7
OUT 4
8
COM 4
IN 1+
9
IN 1–
10
11
IN 2+
12
IN 2–
13
IN 3 +
14
IN 3–
IN 4+
15
IN 4 –
16
17
+10V
COM
18
–10V
19
Figure 2.30.
Reference Signal Connections (PLC Comm Adapter)
1
2
3
4
5
Analog
Analog
Analog
Out 1
Out 2
Out 3
Pin jumper J3 on the PLC Communication Adapter Board Enables or
Disables the BRAM (Battery Backup RAM) Write function as follows:
Jumpered 1 – 2 = Enabled
Jumpered 2 – 3 = Disabled
The PLC Communication Adapter Board 120V/24V jumper settings for I/0
circuits (J8 – J11) are detailed in the 1336 FORCE PLC Communications
Adapter User Manual Publication 1336 FORCE– 5.13.
Switch Settings – There are DIP switches and jumpers located on the PLC
Communications Adapter Board that have been preset at the factory.
Communication is received through Channels A and B. This
communication protocol is defined through SW U2 – U5. If you need to
reconfigure the switches or jumpers consult the 1336 FORCE PLC
Communications Adapter User Manual.
Chapter 2
Installation/Wiring
1
2
3
4
5
6
TB20
Common
Drive
Norm
Enable
Stop*
Motor
Ext
Thermo
Fault
*Refer to Parameter 58 description for explanation of modes
6
7
8
9 10 11 12 13 14 15 16 17 18 19
TB21
Analog
Analog
Analog
Analog
In 1
In 2
Out 4
Ω
Note: If using a pot as an input 2.5K
7
8
9 10
Fault
Relay
Comm
+10
–10
Analog
In 3
In 4
min.
2–43