Hazardous Location Certifications - Emerson Rosemount 8800D Series Quick Start Manual

Vortex flowmeter
Hide thumbs Also See for Rosemount 8800D Series:
Table of Contents

Advertisement

October 2018
9

Hazardous location certifications

9.1
US and Canadian Certifications
E5
Explosion-Proof for Class I, Division 1, Groups B, C, and D
or
Dust ignition-proof for Class II, III Division 1, Groups E, F, G.
E6
Ex db [ia] IIC T6...T1 Gb
Class I, Zone 1, AEx db [ia] IIC T6...T1 Gb (-50 °C ≤ Ta ≤ 70 °C)
Thermal data:
Ambient temperature
(°C)
–50 to +70
–50 to +70
–50 to +70
–50 to +70
–50 to +70
–50 to +70
Factory Sealed; Single Seal
Enclosure Type 4X
Install per drawing 08800-0112;
I5 or
Intrinsically safe for use in Class I, II, III Division 1, Groups A, B, C, D, E,
I6
F, G
Non-incendive for Class I, Division 2, Groups A, B, C and D
Class I, Zone 0, AEx ia IIC T4 Ga
Temperature Code T4 (-50 °C ≤ Ta ≤ 70 °C) 4-20 mA HART
Temperature Code T4 (-50 °C ≤ Ta ≤ 60 °C) Fieldbus
Single Seal; Enclosure Type 4X
Install per drawing 08800-0112
IE or
FISCO for Class I, Division 1, Groups A, B, C, and D
IF
FNICO for Class I Division 2, Groups A, B, C, and D
Class I, Zone 0, AEx ia IIC T4 Ga
Temperature Code T4 (-50 °C ≤ Ta ≤ 60 °C)
Single Seal; Enclosure Type 4X
Install per drawing 08800-0112
Quick Start Guide
Process temperature
(°C)
–200 to +75
–200 to +95
–200 to +130
–200 to +195
–200 to +290
–200 to +427
Quick Start Guide
T-Class sensor (°C)
T6
T5
T4
T3
T2
T1
31