Emerson Rosemount 8800D Series Quick Start Manual page 21

Vortex flowmeter
Hide thumbs Also See for Rosemount 8800D Series:
Table of Contents

Advertisement

October 2018
5.5
Secure cover jam screw
For transmitter housings shipped with a cover jam screw, the screw should be
properly installed once the transmitter has been wired and powered up. The
cover jam screw is intended to disallow the removal of the transmitter cover in
flameproof environments without the use of tooling.
Procedure
1. Verify the cover jam screw is completely threaded into the housing.
2. Install the transmitter housing cover and verify that the cover is tight
against the housing.
3. Using an M4 hex wrench, loosen the jam screw until it contacts the
transmitter cover.
4. Turn the jam screw an additional ½ turn counterclockwise to secure
the cover.
Application of excessive torque may strip the threads.
5. Verify that the cover cannot be removed.
Quick Start Guide
CAUTION
Quick Start Guide