5.12. Failures and remedial measures

Failure
The
splitting
force
insufficient to split the log.
The in-feed conveyor belt does
not move.
The out-feed conveyor belt
does not move
The cutting chain does not
properly penetrate the wood.
The machine starts but none of
the
functions
work.
machine makes an abnormal
noise.
The electric motor does not
start.
The electric motor tends to
stop, and the thermal relay is
easily triggered.
The cutting or splitting function
does not work.
The
sawdust
blower
jammed.
The
machine's
control does not work or works
unreliably
(sawing
splitting button)
Hakki Pilke 43 Pro
Cause
is
1. The log/splitting blade is in an
incorrect position.
2. The splitting force is not great
enough.
1. The belt is too loose.
1. The belt is too loose (the lower
drive roller moves).
2. The lower drive roller is jammed
and does not move.
1. The saw chain is dull.
2. The saw bar is crooked.
The electric motor runs in the
The
wrong direction.
1. The machine makes a loud
noise but does not start.
2. The thermal relay has tripped.
3. Starter fuse triggered.
4. The input cable is faulty.
1. The thermal relay is broken
or incorrectly adjusted.
Some other problem?
1. The machine guard is
open.
is
1. Ensure that the cock is in
the ON position.
2. There is a chip or
obstruction in the sawdust
blower.
3. The motor's relief valve is
leaking (debris inside).
electrical
1. In a PTO machine, the 12
V plug is not connected to
button,
the tractor (in an electrical
model, the 12 V plug is not
connected to the machine)
2. Guard open or sensor fault
3. Connection or grounding
fault in the tractor.
46 / 48
Remedial measure
1. Tension the belt according to
1. Tighten the belt according to
2. Disconnect the machine
1. Sharpen or replace the saw
2. File the bar to make it
1. The gear fuse has blown.
2. Reset the thermal relay with
3. Disconnect from the power
4. Replace the cable.
Translation
1. Fix the position of the
log/splitting blade.
2. Contact the retailer.
the instructions in Section
5.4.1.
the instructions in Section
4.4.
from the power source and
remove the obstruction.
chain.
straight.
See Section 3.2.2.
Replace it.
the starter's stop button.
source and check the
starter relay.
1. Contact the retailer.
1. Close the guard
completely.
1. See Section
3.2.6
2. Clean the blower's
motor.
3. Open and clean the
adjustment cartridge.
1. Connect plug. See
Section
3.2.1
or
2. Fully lower the guard
and check sensor
operation (Figure 60).
3. Check the connections
Upper right in
4.
Figure
23. Determine the cause
Version 6-2018