Solid State Controller Tips; Frozen Iqf Product - Broaster VF3iXP Installation & Operation Manual

Ventless fryer
Table of Contents

Advertisement

SOLID STATE CONTROLLER TIPS

COMPLAINT
Display reads FAIL
Display reads HI
Display reads PROB
Display reads CHEC

FROZEN IQF PRODUCT

Note: This unit is not designed to cook 8 piece
cut chicken, whether fresh or frozen.
COMPLAINT
Product too light
Product too dark
Product not done
No flavor
White spots
Dark spots
CAUSE
1. There is a controller fail-
ure
1. Oil temperature too high
1. There is a temperature
sensor probe failure
1. Oil temperature not rising
properly
CAUSE
1. Low oil temperature
2. Not done
3. Food basket overloaded
1. High oil temperature
2. Overcooked
3. Oil old
4. Thawed and refrozen
1. Low oil temperature
2. Food basket overloaded
3. Cook time too short
1. Overcooked
2. Old product
1. Food basket overloaded
1. Dirty oil
12 - 3
Manual #16887 5/08 Rev 4/09
REMEDY
1. Push power OFF button
Contact service person
1. Push power OFF button
Contact service person
1. Push power OFF button
Contact service person
1a. Check wall fuse or circuit
breaker
1b. Push power OFF button
Contact service person
REMEDY
1. Check cook temperature
2. Increase cook time
3. Decrease load
1. Check cook temperature
2. Decrease cook time
3. Change oil
4. Keep product at 0°F or
below
1. Check cook temperature
2. Decrease load
3. Increase cook time
1. Check cook time
2. Discard
1. Decrease load size
1. Filter or replace oil

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vf-2xp

Table of Contents