Fire-Lite Alarms MS-5210UD Manual page 81

Fire alarm control panel
Table of Contents

Advertisement

History Mode
Shown below is the list of messages as they will appear on the display:
History Mode Messages
TABLE 5-1:
DISPLAY
EVENT
ACn_
Acknowledge key pressed
A__!
Zone 1 Alarm
A__2
Zone 2 Alarm
A__3
Zone 3 Alarm
A__4
Zone 4 Alarm
A__5
Zone 5 Alarm
A__6
Zone 6 Alarm
A__7
Zone 7 Alarm
A__8
Zone 8 Alarm
A__9
Zone 9 Alarm
A_10
Zone 10 Alarm
SU_1
Supervisory 1 Alarm
SU_2
Supervisory 2 Alarm
SU_3
Supervisory 3 Alarm
SU_4
Supervisory 4 Alarm
SU_5
Supervisory 5 Alarm
SU_6
Supervisory 6 Alarm
SU_7
Supervisory 7 Alarm
SU_8
Supervisory 8 Alarm
SU_9
Supervisory 9 Alarm
SU10
Supervisory 10 Alarm
PA_1
Process Alarm Zone 1
PA_2
Process Alarm Zone 2
PA_3
Process Alarm Zone 3
PA_4
Process Alarm Zone 4
PA_5
Process Alarm Zone 5
PA_6
Process Alarm Zone 6
PA_7
Process Alarm Zone 7
PA_8
Process Alarm Zone 8
PA_9
Process Alarm Zone 9
PA10
Process Alarm Zone 10
_AC_
AC Loss
F__1
Zone 1 Fault
F__2
Zone 2 Fault
F__3
Zone 3 Fault
F__4
Zone 4 Fault
F__5
Zone 5 Fault
F__6
Zone 6 Fault
F__7
Zone 7 Fault
F__8
Zone 8 Fault
F__9
Zone 9 Fault
F_10
Zone 10 Fault
bEL1
Bell 1 Fault (open or short)
bEL2
Bell 2 Fault (open or short)
bEL3
Bell 3 Fault (open or short)
bEL4
Bell 4 Fault (open or short)
2
To erase the list from E
memory, press the SILENCE key twice before exiting the History Mode. A lack of key-
board activity for a period of 10 minutes will cause the control panel to return to Normal Mode. If a printer is con-
nected to the panel, the History File will be printed upon successful entry into History Mode and a list of the most
recent 256 events, time and date stamped, will print out.
Note that remote site upload or download is possible when the system is in History Mode.
DISPLAY
EVENT
F__E
Earth Fault
F__A
Annunciator Fault
F__P
Printer Fault
F_85
Annunciator Bus Fault
d__1
Zone 1 disabled
d__2
Zone 2 disabled
d__3
Zone 3 disabled
d__4
Zone 4 disabled
d__5
Zone 5 disabled
d__6
Zone 6 disabled
d__7
Zone 7 disabled
d__8
Zone 8 disabled
d__9
Zone 9 disabled
d_10
Zone 10 disabled
drLL
Fire Drill
E__1
Enable Zone 1
E__2
Enable Zone 2
E__3
Enable Zone 3
E__4
Enable Zone 4
E__5
Enable Zone 5
E__6
Enable Zone 6
E__7
Enable Zone 7
E__8
Enable Zone 8
E__9
Enable Zone 9
E_10
Enable Zone 10
d_b1
Disable bell 1
d_b2
Disable bell 2
d_b3
Disable bell 3
d_b4
Disable bell 4
E_b1
Enable bell 1
E_b2
Enable bell 2
E_b3
Enable bell 3
E_b4
Enable bell 4
PH_1
Primary C.S. Number Communication Fault
PH_2
Secondary C.S. Number Communication Fault
no_b
No Battery
Lo_b
Low Battery
SILE
Silence Switch Pressed
SIL1
NAC/Bell #1 Silenced
SIL2
NAC/Bell #2 Silenced
SIL3
NAC/Bell #3 Silenced
SIL4
NAC/Bell #4 Silenced
no_1
Primary Phone Line Fault
no_2
Secondary Phone Line Fault
rES_
Reset Switch Pressed
POr_
Power On Reset (unit was powered off
completely, i.e. no AC and no battery)
Document #50193
Rev. E
01/30/02
P/N 50193:E
81