Chapter 4
Using the HIM
Viewing/Clearing Drive
Faults or Alarms
46
Follow these steps to view/clear drive faults or alarms.
1. Access the Status screen (see
2. If Port 00 (host drive) is not shown above the ESC soft key, use the
or
key to scroll to Port 00.
3. Press the
key to display its last-viewed folder.
4. Use the
or
5. Use the
or
6. Press the
(Enter) key to display the numbered fault/alarm queue.
Faulted
0.00 Hz
Port 00
01
82
Port 2 DPI Loss
02
49
Drive Powerup
03
9
Trnsistr OvrTemp
04
8
Heatsink OvrTemp
ESC
TOP
END
Faults/alarms are listed from the most recent to occur (line 01) to the least
recent. The fault/alarm number and name are shown at the right.
7. Use the
or
the fault/alarm queue.
Soft Key
Function
ENTER
Displays the Time Stamp popup box for the fault/alarm. Note that the real-time clock in a
PowerFlex 750-Series drive must be accurately set to provide meaningful time stamp data. For
details, see
Use the
(if supported by device).
TOP
Displays the first (most recent) fault/alarm in the queue.
END
Displays the last (least recent) fault/alarm in the queue.
8. To clear faults/alarms, press the CLR soft key.
In the Select Action popup box, select the appropriate action using the
or
fault/alarm or clear the fault/alarm queue. To cancel the popup box, press
the ESC soft key or select Cancel from the list and press the
key.
Rockwell Automation Publication 20HIM-UM001E-EN-P - May 2017
Figure
6).
key to scroll to the DIAGNOSTIC folder.
key to select Faults or Alarms.
AUTO
F
Faults
CLR
ENTER
key or the following soft keys to navigate within
Setting the Date/Time for PowerFlex 750-Series Drives on page
or
key to scroll to all parameters related to the displayed fault/alarm
key and press the
(Enter) key to clear the active
35.
(Enter)