Mounting/Wiring; Specification - SMC Networks EX500 Series Instruction Manual

Reduced wiring system devicenet compatible gw unit
Hide thumbs Also See for EX500 Series:
Table of Contents

Advertisement

Mounting/Wiring

The mounting and removing methods of SI unit are as shown below.
Supply/exhaust block
assembly
SI Unit for SV Series Valves ( EX500-S
M3
10: 2 pcs.
( Hexagon socket head cap
screw ( with spring washer ))
SI Unit for VQC Series Valves ( EX500-Q
NOTE
Holding with hand so that there will be no gap between SI unit and Air supply/exhaust
block assembly, tighten the bolts. Be sure to tighten each bolt by specified tightening
torque. ( Tightening torque: 0.6Nm )
For branch wiring method, refer to subsection "Wiring" ( page 11 ) of section "EX500"
Note 1
in this manual. As the power to output devices such as solenoid valve is supplied by
branch wiring ( branch cable with M12 connector ), there is no need to supply power
individually.
For mounting/installation methods of solenoid valve, manifold, etc., refer to the
Note 2
catalogs, instruction manuals, technical data, etc. of each valve series.
When connecting general purpose output block only, refer to subsection "Mounting"
( page 33 ) of section "EX9 Series General Purpose Output Block" in this manual.
22
M3
30: 4 pcs.
( Plus-minus slot
round head screw )
01 )
Supply/exhaust block
assembly
01 )

Specification

1. SI unit for SV series valve ( EX500-S
Item
Connected block
Solenoid valve ( single, double )
Relay output module ( 1-point output, 2- point output )
Connected block
Double solenoid valve
station
Relay output module ( 2-point output )
Single solenoid valve
Relay output module ( 1-point output )
Supply voltage for block
DC24V
Supply current for block
0.65A Max.
Current consumption
100mA or less ( at rated voltage )
2. SI unit for VQC series valve ( EX500-Q
Item
Connected block
Solenoid valve ( single, double )
General purpose output block ( EX500-Q
Connected block
Double solenoid valve
station
Single solenoid valve
General purpose output block
( EX500-Q
Supply voltage for block
DC24V
Supply current for block
0.75A Max.
Current consumption
100mA or less ( at rated voltage )
3. Applicable valve series
Manifold
Series
Cassette
SV1000
SV2000
-
SV3000
-
SV4000
-
VQC1000
-
VQC2000
-
VQC4000
For detailed specifications of solenoid valve and manifold, refer to the catalogs, instruction
manuals, technical data, etc. of each valve series.
01 )
Specification
Max. 8 stations
Max. 16 stations
)
Specification
02 only )
Max. 8 stations
Max. 16 stations
Max. 8 stations
02 only )
Inner diameter of applicable cylinder tube ( mm )
Tie-rod
40
50
63
80
100
125
23