SMC Networks EX180-SMJ3 Series Operation Manual

Si unit for cc-link

Advertisement

Quick Links

No.EX※※-OMO0007-D
PRODUCT NAME
SI unit for CC-Link
MODEL / Series / Product Number
EX180-SMJ3/5□ Series

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EX180-SMJ3 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for SMC Networks EX180-SMJ3 Series

  • Page 1 No.EX※※-OMO0007-D PRODUCT NAME SI unit for CC-Link MODEL / Series / Product Number EX180-SMJ3/5□ Series...
  • Page 2: Table Of Contents

    Contents Safety Instructions How to Order Summary of Product Parts Definition and terminology Installation and Cabling General Instructions on installation Connecting cables LED Display and Settings Troubleshooting and Maintenance Maintenance Specifications Table of specifications Dimensions No.EX※※-OMO0007-D...
  • Page 3: Safety Instructions

    Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of "Caution", "Warning" or "Danger". They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC) , and other safety regulations.
  • Page 4 Safety Instructions Caution 1.The product is provided for use in manufacturing industries. The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary. If anything is unclear, contact your nearest sales branch.
  • Page 5 Operator This operation manual is intended for those who have knowledge of machinery using pneumatic equipment, and have sufficient knowledge of assembly, operation and maintenance of such equipment. Only those persons are allowed to perform assembly, operation and maintenance. Read and understand this operation manual carefully before assembling, operating or providing maintenance to the product.
  • Page 6 ■NOTE ○Follow the instructions given below when designing, selecting and handling the product. The instructions on design and selection (installation, wiring, environment, adjustment, operation, described below must also be followed. maintenance, etc.) Product specifications When conformity to UL is necessary the SI unit must be used with a UL1310 Class2 power supply. The SI unit is a UL approved product only if they have a mark on the body.
  • Page 7 Environment Do not use the product in area that is exposed to corrosive gases, chemicals, sea water, water or steam. Otherwise failure or malfunction can result. Do not use in an area where surges are generated. If there is equipment which generates a large amount of surge (solenoid type lifter, high frequency induction furnace, motor, etc.) close to the fieldbus system, this may cause deterioration or breakage of the internal circuit of the fieldbus system.
  • Page 8: How To Order

    How to Order EX180 series SI unit Accessories: Communication connector Accessories: Power supply connector No.EX※※-OMO0007-D...
  • Page 9: Summary Of Product Parts

    Summary of Product Parts Communication connector for CC-Link (1 pc.) EX180-SMJ3/5 EX180-SMJ3A/5A (EX180-CMJ1) (EX180-CMJ2) Power supply connector (2 pcs.) (EX180-CP1) Accessories Element Description Fieldbus interface connector The connector for CC-Link ( ) that is used to connect to the CC-Link bus line. (BUS) The connector for the power supply ( ) that is used to supply the power for...
  • Page 10: Installation And Cabling

    Installation and Cabling ■General Instructions on installation ○Applicable valve series The EX180 series SI unit can be mounted on the following valve manifolds. Manifold SJ2000, SJ3000, S0700 series *: Refer to the catalogues and operation manuals for details on the solenoid valves and manifolds. How to mount the manifold 1.
  • Page 11: Connecting Cables

    ■Connecting cables 1. Wiring for communication Wiring of the CC-Link cable and communication connector is shown below. (1)Connect the signal lines to the assigned pins. (Figure 1) The CC-Link communication connector is suitable for use with wire sizes from AWG24 to 12 (0.2 mm to 2.5 mm The required tightening torque is 0.5 to 0.6 Nm.
  • Page 12 (4)How to connect. ●Note Connect the shield line for CC-Link cable to "SLD" of each unit. Figure 4 2. Wiring of the power supply Connect the power supply to the power supply connector (2 pcs.). The power supply connector is suitable for use with wire sizes from AWG28 to 16 (0.14 mm to 1.5 mm The EX180 power supply structure consists of two systems.
  • Page 13: Led Display And Settings

    LED Indication and Settings ○LED Indication Description LED status Solenoid valve power supply is supplied at specified voltage PWR(V) Solenoid valve power supply is not supplied at specified voltage SI unit power supply supplied within the specified range SI unit power supply not connected or out of range Normal communication L RUN Communication terminated (Time over error)
  • Page 14 ○Switch setting Turn off the power supply while setting the DIP switches. Open the cover and set the DIP switches with a small flat blade screwdriver. -13- No.EX※※-OMO0007-D...
  • Page 15 ○Output information I/O mapping table for master station Buffer Memory. EX180-SMJ3□/5□ is a remote I/O station (1 station occupied, 32 inputs/32 outputs). An example of when the SI unit station number is set to 01 is shown below. Master station buffer area I/O memory map of EX180-SMJ3□/5□...
  • Page 16 ○Output number assignment : The output number refers to the solenoid position on the manifold and starts at zero. : Standard wiring on the manifold is for double-solenoid valves and output number starts A side and B side in that order as shown in the Figure a.
  • Page 17: Troubleshooting And Maintenance

    Troubleshooting and Maintenance ○Troubleshooting Chart Applicable SI unit: EX180-SMJ3□/5□ When any malfunction is observed, perform the following troubleshooting. When the troubleshooting does not apply to your problem and the operation returns to normal after replacing the SI unit, it is presumed that SI unit has malfunctioned. It may be possible that the malfunctioning of the SI unit is caused by the operating environment (network structure).
  • Page 18 ○Cross-Reference for Troubleshooting Reference Problem Possible cause Investigation method Countermeasure Check the cable for the power supply controlling the SI unit, and confirm that the connection between the power Incorrect wiring supply cable and the connector is not Connect the power of the power loose.
  • Page 19 Reference Problem Possible cause Investigation method Countermeasure Failure of the power supply Confirm that power is supplied to the Supply power to the for the master master station master station correctly. station Check the communication cable is not broken, and that there are no loose connections between the power Connect the supply cable and connector.
  • Page 20 Reference Problem Possible cause Investigation method Countermeasure Incorrect Confirm the communication speed change of the Shut off the power setting has not been changed whilst communication supply for the SI unit. power is supplied to the SI unit. speed After setting correctly supply power to the SI L RUN L ERR...
  • Page 21: Maintenance

    ■Maintenance Mounting/Wiring Item Criterion Remedy Check the SI unit connector for the Perform extra tightening. communication and the power Not loose. (Refer to "Wiring" of this operation supply are connected properly. manual) Confirm that the terminal resistor is properly connected to both ends of Not loose.
  • Page 22: Specifications

    Specifications ■Table of specifications Item Specifications Applicable system CC-Link Ver.1.10 Occupied number of stations 1 node Allowable node number setting 1 to 64 Station type Remote I/O node Transmission speed 156 kbps 625 kbps 2.5 Mbps 5 Mbps 10 Mbps Min.
  • Page 23: Dimensions

    Dimensions Unit: mm EX180-SMJ3/5 EX180-SMJ3A/5A -22- No.EX※※-OMO0007-D...
  • Page 24 Revision history A: Revision B: Limited warranty and Disclaimer are added. C: Contents are added. D: Contents are added. [June 2017] Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. © 2010-2017 SMC Corporation All Rights Reserved No.EX※※-OMO0007-D...

This manual is also suitable for:

Ex180-smj5 seriesEx180-smj3aEx180-smj3Ex180

Table of Contents