Interface Status
Upon Receipt of an SOH (hexadecimal 01) followed immediately by an IG
(hexadecimal 4947) causes the printer to return a 1 byte Interface Status Word
bounded by an STX-ETX pair that reports the type of interface connection currently
set in the printer.
BYTE
NUMBER
1
Serial Interface Settings
Upon Receipt of an SOH (hexadecimal 01) followed immediately by an H2
(hexadecimal 4832) causes the printer to return a 5 byte Serial IF Status Word
bounded by an STX-ETX pair that reports the current operating parameters of the
Serial RS232 Interface.
BYTE
NUMBER
1
2
3
4
SATO CT Series Printers
VALUE
0
IEEE 1284 Parallel
1
Serial RS232
2
Local Area Network
3
Universal Serial Bus
VALUE
0
9600 BPS
1
19200 BPS
2
38400 BPS
3
57600 BPS
4
115200 BPS (not currently available)
0
No Parity
1
Odd Parity
3
Even Parity
0
1 Stop Bit
1
2 Stop Bits
0
Single Item Buffer with Ready/Busy Flow Control
1
Multi-Item Buffer with Ready/Busy Flow Control
2
X-ON/X-OFF Flow Control
3
Status 4 Bi-Comm
4
Status 3 Bi-Comm
9001069A
Section 5. Interface Specifications
DESCRIPTION
DESCRIPTION
Page 5-17