Command Structure
Command Function
Input to Printer
Printer Output
Special Notes
SATO CT Series Printers
Print Darkness
<ESC>#Eab
a
=
Print Darkness Range (A thru F)
b
=
Print darkness value (1 thru 5)
Example:
<ESC>#E2A
Placement:
Must be placed immediately after <ESC>A and
immediately before <ESC>Z in its own separate data stream
Default:
Value set in printer using the <ESC>PG Printer Setting
To specify a new print darkness setting. This command allows
software control of the darkness setting for unique media and ribbon
combinations.
<ESC>A
<ESC>#EA2
<ESC>Z
There is no printer output for this command.
1. This becomes the new setting in the printer configuration for all
subsequent print jobs, unless changed. The setting is stored in
non-volatile memory and is not affected by cycling power.
2. The allowable Print Darkness Level setting is "A" for SATO
ThechoTherm direct thermal media and "B" for SATO
TechnoTherm coated thermal transfer media.
9001069A
Section 4. Programming Reference
Page 4-57