9.1 UPS Status Indicators and Alarms

There are four status indicators (lights) on the front of the UPS.
On Line (GREEN) – is lit whenever utility power is powering the
Battery Backup outlets.
On Battery (YELLOW) – is lit whenever the battery of the UPS is
powering equipment connected to the Battery Backup
Outlets.
Four Beeps Every 30 Seconds – this alarm is sounded
whenever the UPS is running on Battery. There is approximately 10 minutes of run time on batteries.
Suggest waiting 1-2 minutes in case the main power is restored then start shutting the Dell computer
down in an orderly manner.
Continuous Beeping – this alarm is sounded whenever a low battery condition is reached. Battery run-
time is very low. The Dell must be entirely shut down by this time.
Overload (RED) – is lit whenever power demand has exceeded the capacity of the UPS.
Continuous Tone – this alarm is sounded whenever the Battery Backup outlets are overloaded.
Circuit Breaker – the circuit breaker button located on the rear panel of the UPS will stick out if an
overload condition forces the UPS to disconnect itself from utility power. Reset the circuit breaker by
pushing the button inward.
Replace Battery (RED)
not connected. A battery that is near end of its useful life has insufficient runtime and should be
replaced.
(CALL FOR SERVICE IF THIS OCCURS!)
Chirps for 1 Minute Every 5 Hours – this alarm is sounded whenever the battery has failed the
automatic diagnostic test.
– is lit whenever the battery is near the end of its useful life, or if the battery is