Installation Requirements - Barco ImagePRO User Manual

4k video processor
Hide thumbs Also See for ImagePRO:
Table of Contents

Advertisement

Product
Contains
R9004795
1RU rack mount
chassis
(Image-
PRO–4K)
1x 14-9750004-90
1x B1959864
1x B1959865
1x R9871179
2x 09-0904021-90
4x 13-0211010-90
B561132
Mechanical check
This check should confirm that there are no broken parts and the unit is free of dents or scratches. Your Barco
Sales representative should be notified as soon as possible if this is not the case.

3.5 Installation requirements

Environmental conditions
The unit must always be mounted in a manner which ensures both air inlets and outlets are free. For
installations in environments where the device is subject to excessive dust, it is highly advisable to take
measures to prevent the dust from reaching the unit. If this is not a feasible, then the unit should be relocated
to a different dust-free location.
It is the customer's responsibility to ensure at all times that the device is protected from the harmful effects of
hostile airborne particles in the environment of the device. The manufacturer reserves the right to refuse repair
if a device has been subject to negligence, abandon or improper use.
The table below summarizes the physical environment in which the ImagePRO–4K video processor may be
safely operated or stored.
Environment
Ambient Temperature
Air cleanliness
Humidity
Altitude
Site preparation
The environment in which you install your ImagePRO–4K video processor should be clean, properly lit, free
from static, and have adequate power, ventilation, and space for all components.
Do not install the device in a site near heat sources such as radiators or air ducts, or in a place subject to
direct sunlight, excessive dust or humidity. Be aware that room heat rises to the ceiling; check that
temperature near the installation site is not excessive.
Accessories included
ImagePRO–4K assembly
European Power Cord CEE7 (not included with units shipped to
China)
US Power Cord NEMA 5/15 (not included with units shipped to China)
China Power Cord GB 2099 (only included with units shipped to
China)
Rear Rack Mount Support Kit, includes brackets, side support plates,
screws, and washers
Rear connector protectors
8-32 x .38 Pan Head Screws for rear connector protectors (x2 per
protector)
USB Thumb Drive (Contains Users Guide, System Software and
Control GUI)
Operating
0°C (32°F) to 40°C (104°F)
Clean office environment (equivalent
with cleanroom standard ISO 14644-1
ISO Class 9)
5% to 85% RH Non-Condensed
-60 (-197Ft) to 2000m (6561Ft)
Non-Operating
-10°C (14°F) to 60°C (140°F)
n.a.
0% to 95% RH Non-Condensed
-60 (-197Ft) to 10000m (32810Ft)
R5906167 /00
ImagePRO–4K Video Processor
General
17

Advertisement

Table of Contents
loading