Technical Data - turck Li-Q25LxE Series Operating Instructions Manual

Linear position sensor with analog output
Table of Contents

Advertisement

14

Technical Data

Measuring range
Measuring range
Resolution
Nominal distance
Blind zone a
Blind zone b
Repetition accuracy
Linearity tolerance
Temperature drift
Hysteresis
Ambient temperature
Operating voltage
Ripple
Insulation test voltage
Short-circuit protection
Wire breakage / reverse polarity protection
Output function
Voltage output
Current output
Load resistance voltage output
Load resistance current output
Sampling rate
Current consumption
Design
Dimensions
Housing material
Material of active face
Electrical connection
Vibration resistance (EN 60068-2-6)
Shock resistance (EN 60068-2-27)
Degree of protection
MTTF
Packed quantity
Operating voltage indication
Measuring range indication
2018/10
100...1000 mm in 100 mm steps; 1250...2000 mm in 250 mm steps;
16 bit
1.5 mm
29 mm
29 mm
≤ 0.02 % of full scale
depending on measuring length (see data sheet)
≤ ± 0.003 %/K
not applicable due to operating principle
-25...+70 °C
15...30 VDC
≤ 10 % U
ss
≤ 0.5 kV
Yes
yes/yes (power supply)
5-pin, analog output
0...10 V
4...20 mA
≥ 4.7 kΩ
≤ 0.4 kΩ
5 kHz
< 50 mA
Rectangular, Q25L
(measuring length + 58) × 35 × 25 mm
Anodized aluminum
Plastic, PA6-GF30
Male connector, M12 × 1
20 g, 1.25 h per axis; 3 axes
200 g, 4 ms 1/2 sine
IP67
IP66
138 years to SN 29500 (Ed. 99) 40 °C
1
LED: Green
Multifunction LED: Green, yellow, yellow flashing
19