turck LRS510 Series Instructions For Use Manual

Radar level sensors
Table of Contents

Advertisement

Quick Links

Your Global Automation Partner
LRS510...
Radar Level Sensors
Instructions for Use

Advertisement

Table of Contents
loading

Summary of Contents for turck LRS510 Series

  • Page 1 Your Global Automation Partner LRS510… Radar Level Sensors Instructions for Use...
  • Page 2 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 3: Table Of Contents

    Feedback about these instructions................ 5 Notes on the Product .........................  6 Product identification.....................  6 Scope of delivery ...................... 6 Legal requirements...................... 6 Turck service........................ 6 For Your Safety............................  7 Intended use........................ 7 Obvious misuse........................  7 General safety instructions....................  7 Product Description ...........................  8 Device overview ......................
  • Page 4 15 Appendix: Conformity and Approvals.................. 45 15.1 EU Declaration of Conformity .................. 45 15.2 FCC Digital Device Limitations.................. 45 16 Turck Subsidiaries - Contact Information .................. 46 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 5: About These Instructions

    This symbol denotes actions that the user must carry out. RESULTS OF ACTION This symbol denotes relevant results of actions. Other documents Besides this document the following material can be found on the Internet at www.turck.com: Data sheet Commissioning manual IO-Link devices IO-Link parameters manual...
  • Page 6: Notes On The Product

    CAD files in numerous export formats. The contact details of Turck subsidiaries worldwide can be found on p. [} 46]. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 7: For Your Safety

    The product is designed according to state-of-the-art technology. However, residual risks still exist. Observe the following warnings and safety notices to prevent damage to persons and property. Turck accepts no liability for damage caused by failure to observe these warning and safety notices.
  • Page 8: Product Description

    55.1 [2.17] Ø 38 [1.50] M12 × 1 114.5 [4.51] 12.2 [0.48] 21.1 [0.83] 27.3 [1.07] mm [Inch] Fig. 2: Dimensions LRS510-…69… Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 9: Properties And Features

    55.1 [2.17] Ø 38 [1.50] M12 × 1 110.7 [4.36] 12.2 [0.48] 17.1 [0.67] 21.6 [0.85] NPT 3/4 mm [Inch] Fig. 3: Dimensions LRS510-…34… 55.1 [2.17] Ø 38 [1.50] M12 × 1 110.7 [4.36] 12.2 [0.48] 24.9 [0.98] NPT 1 30.1 [1.22] mm [Inch] Fig. 4: Dimensions LRS510-…57…...
  • Page 10: Operating Principle

    Gutbereich acceptable range Fig. 5: Behavior of the switching output – window function Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 11: Output Functions - Analog Output

    Hysteresis function The hysteresis function is used to teach in a stable switching state that is not affected by sys- tem-related fluctuations and the defined setpoint. The switching range is defined with a switching point and a reset point. The minimum hysteresis is 0.5 % of the measuring range. If the switching point is changed, the reset point is automatically adjusted.
  • Page 12: Sio Mode (Standard I/O Mode)

    More information on this is available from the Turck product database at www.turck.de/products in the Connectivity area. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 13: Installing

    Installing The lens curvature does not have to be taken into account for the installation. The sensor de- tects the surface of the medium nearest to the sensor and outputs the distance. Object reflec- tions can be filtered out using the sensor parameters. The sensors can be installed in any alignment according to application requirements.
  • Page 14: Connection

    7 BU out 3: switch 6 PK out 4: switch n.c. n.c. – Fig. 14: LRS…4UPN… pin layout Fig. 15: LRS…4UPN wiring diagram Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 15: Commissioning

    Commissioning After connecting and switching on the power supply, the device is automatically ready for operation. V01.00 | 2021/07...
  • Page 16: Operation

    Burden at the analog output outside of the permissible range ErrT No object detected Short circuit Device locked uLoc Device unlocked - - - - Sensor failure Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 17: Setting And Parameterization

    Setting and Parameterization Settable functions and features Setting options via touchpads and IO-Link interface The following functions and properties can be set and used both in standard I/O mode as well as in IO-Link mode: Locking/unlocking the device Window function Hysteresis function Analog range Advanced settings: Reset to the previous settings (presettings)
  • Page 18: Setting Via Touchpads

    Release the touchpads when six green bars are flashing on the display. LOC LED goes out. uLoc appears in the display and goes out. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 19: Standard Menu - Overview

    9.2.3 Standard menu – overview Standard menu guidance – main menu Process value > 3 s Current value Save value SP1/FH1 rP1/FL1 > 3 s Current value Save value … Auto 4…20 … rtio SP2/FH2 rP2/FL2 > 3 s Current value ou3 (option) Save value SP3/FH3...
  • Page 20 FACT Current value > 3 s Software version VDMA Save value years days hours OPHr Fig. 17: EF extended functions menu Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 21: Vdma Menu - Overview

    9.2.4 VDMA menu – overview VDMA menu – main menu Process value SP1/FH1 rP1/FL1 SP2/FH2/ASP rP2/FL2/AEP SP3/FH3 rP3/FL3 SP4/FH4 rP4/FL4 Fig. 18: VDMA main menu V01.00 | 2021/07...
  • Page 22 Save value > 3 s Software PASS version VDMA Save value years days hours OPHr Fig. 19: VDMA EF extended functions menu Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 23: Setting Parameter Values Via Touchpads

    9.2.5 Setting parameter values via touchpads Turck standard menu „ Unlock the device when [MODE] or [SET] is touched, a red running light appears and the LOC LED is lit. „ Touch [MODE] or [SET] until the required parameter is displayed.
  • Page 24: Setting Parameter Values Via Touchpads - Geom Menu

    Set value Set value hBot LnGt Set value Set value DToP FLAT DISH Set value hToP Set value Fig. 22: GEOM menu Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 25: Protecting The Sensor With A Password

    9.2.7 Protecting the sensor with a password „ Select PASS in the EF menu. „ Change values via [SET]. „ Use [MODE] to navigate between the four digits of the password. „ Use [ENTER] to store the new password. > 3 s Gradually upwards (hex.) Pos.
  • Page 26: Parameters In The Main Menu

    Hysteresis function (NO = NO contact) Hysteresis function (NC = NC contact) Window function (NO = NO contact) Window function (NC = NC contact) Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 27 Explanation Options Function Function of output 4 Hysteresis function (NO = NO contact) Hysteresis function (NC = NC contact) Window function (NO = NO contact) Window function (NC = NC contact) Submenu for additional See table “Parameters in the EF submenu” setting options V01.00 | 2021/07...
  • Page 28: Parameters In The Ef Submenu (Extended Functions)

    0…8 s in increments of 0.01 s (0 = filter is deactivated) Default: 0.0 Behavior of the switching output Auto Automatic detection (NPN/PNP) N switching P switching Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 29 Explanation Options Function Display orientation Display rotated by 0° diSr 0° 180° Display rotated by 180° diSu Measured value display 50 ms update time 200 ms update time 600 ms update time Display update deactivated coLr Display color GrEn Always green Always red G1ou Green if ou1 is switched, otherwise red...
  • Page 30: Parameters In The Geom Submenu (Geometry)

    Diameter of cylindrical and spherical containers; DIA (CYLV, CYLH, SPHR) must be ≥ FuLL for CYLH and SPHR. Default: 564.1895 mm Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 31 Explanation Options Function Container length Total length of cylindrical containers; with CYLV LnGt LnGt (CYLV, CYLH) must be ≥ FuLL. Default: Measuring range minus blind zone Type of container bottom FLAT Flat bottom (CYLV, CYLH) DISH Two dish-shaped (convex bottoms at both ends) DBot Diameter at the bottom edge of Lower diameter of conical containers...
  • Page 32: Setting Via Io-Link

    Enter the password in the Login field on the start page of the web server. The default password is “password”. „ Click Login. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 33: Reading In Iodd In The Web Server

    9.4.2 Reading in IODD in the web server „ Set the input port of the IO-Link master as an IO-Link port. „ Open the IODD Configurator tab in the web server. Fig. 28: Web server – IODD Configurator V01.00 | 2021/07...
  • Page 34 Setting and visualization with the Turck Radar Monitor „ Load the specific device IODD in the web server via Load IODD. Fig. 29: Loading IODD Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 35: Turck Radar Monitor - Overview

    9.4.3 Turck Radar Monitor – overview The Turck Radar Monitor makes it possible to visualize the process data and filter signals. The display consists of: FFT diagram and envelope curve Object detection „ To launch the Turck Radar Monitor, choose Radar monitor.
  • Page 36: Turck Radar Monitor - Filtering Signals

    The signal limits are displayed in a white area in the Turck Radar Monitor. Peaks without a blue bar are not forwarded for data processing. Fig. 31: Example– filtering signals Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 37: Troubleshooting

    Troubleshooting If the device does not function as expected, first check whether ambient interference is present. If there is no ambient interference present, check the connections of the device for faults. If there are no faults, there is a device malfunction. In this case, decommission the device and replace it with a new device of the same type.
  • Page 38: Maintenance

    Disposal The devices must be disposed of correctly and must not be included in general household garbage. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 39: Technical Data

    Technical Data 14.1 Technical data – LRS510-10-…-2UPN8-H1141 Technical data LRS510-10-34… LRS510-10-51… LRS510-10-57… LRS510-10-69… Ident No. 100012732 100012731 100012726 100012725 Radar data Frequency range 122…123 GHz Range 35…1000 cm Resolution 1 mm Minimum size 500 mm measuring range Minimum size 500 mm switching range Linearity tolerance ≤...
  • Page 40: Technical Data - Lrs510-10

    20 g (10…2000 Hz), EN 600068-2-6 EN 61000-6-2:2019 ETSI EN 301489-3 V1.6.1 Approvals CE, UL, ETSI I 305550-2, FCC/CFR. 47 Part 15 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 41: Technical Data - Lrs510-10

    14.2 Technical data – LRS510-10-…-4UPN8-H1181 Technical data LRS510-10-34… LRS510-10-51… LRS510-10-57… LRS510-10-69… Ident No. 100012734 100012733 100012728 100012727 Radar data Frequency range 122…123 GHz Range 35…1000 cm Resolution 1 mm Minimum size 500 mm measuring range Minimum size 500 mm switching range Linearity tolerance ≤...
  • Page 42 20 g (10…2000 Hz), EN 600068-2-6 EN 61000-6-2:2019 ETSI EN 301489-3 V1.6.1 Approvals CE, UL, ETSI I 305550-2, FCC/CFR. 47 Part 15 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 43 14.3 Technical data – LRS510-10-…-LI2UPN8-H1141 Technical data LRS510-10-34… LRS510-10-51… LRS510-10-57… LRS510-10-69… Ident No. 100012730 100012729 100012723 100012722 Radar data Frequency range 122…123 GHz Range 35…1000 cm Resolution 1 mm Minimum size 500 mm measuring range Minimum size 500 mm switching range Linearity tolerance ≤...
  • Page 44 20 g (10…2000 Hz), EN 600068-2-6 EN 61000-6-2:2019 ETSI EN 301489-3 V1.6.1 Approvals CE, UL, ETSI I 305550-2, FCC/CFR. 47 Part 15 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 45: Appendix: Conformity And Approvals

    15.1 EU Declaration of Conformity Hans Turck GmbH & Co. KG hereby declares that the level sensors of the LRS510-… series comply with Directive 2014/53/EU. The complete text of the EU declaration of conformity can be obtained from the following Internet address: www.turck.com...
  • Page 46: Turck Subsidiaries - Contact Information

    Turck Banner Malaysia Sdn Bhd Unit A-23A-08, Tower A, Pinnacle Petaling Jaya, Jalan Utara C, 46200 Petaling Jaya Selangor www.turckbanner.my Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 47 Mexico Turck Comercial, S. de RL de CV Blvd. Campestre No. 100, Parque Industrial SERVER, C.P. 25350 Arteaga, Coahuila www.turck.com.mx Netherlands Turck B. V. Ruiterlaan 7, NL-8019 BN Zwolle www.turck.nl Austria Turck GmbH Graumanngasse 7/A5-1, A-1150 Wien www.turck.at Poland TURCK sp.z.o.o.
  • Page 48 Over 30 subsidiaries and over 60 representations worldwide! 100018911 | 2021/07 100018911 www.turck.com...

Table of Contents