  • Page 2: Table Of Contents

    Carefully remove the contents of the shipping carton and check each item on the packing slip before destroying the packing materials . Any damage must be reported to the shipping company . If you do not receive all of the parts, contact Turck at 763-553-7300 .
  • Page 3: Chapter 1: Ltx R10 Analog Overview

    The part number on the LDT is a record of the characteristics that make up your specific unit . For a translation of the part number, see section 3 .5: Part Number Key . B1407 3 www.turck.com • Phone: 763-553-7300 • Application Support: 1-800-544-7769 • Fax: 763-553-0708 • Turck Minneapolis, MN 55441...
  • Page 4 Figure 1-1 LTX R10 Analog Dimension Drawing 4 B1407 www.turck.com • Phone: 763-553-7300 • Application Support: 1-800-544-7769 • Fax: 763-553-0708 • Turck Minneapolis, MN 55441...
  • Page 5: Chapter 2: Installing

    . The diameter of this magnet assembly should not be more than 0 .2" away from the rod . Split magnet assemblies outside of this range will cause signal loss . B1407 5 www.turck.com • Phone: 763-553-7300 • Application Support: 1-800-544-7769 • Fax: 763-553-0708 • Turck Minneapolis, MN 55441...
  • Page 6: Installing In A Hydraulic Cylinder

    1 . LTX R10 2 . LB-R10 3 . STM-AL-R10 4 . STS-R10 5 . MMB-R10 6 . RB-R10 Figure 2-1: Mounting the EZ-track 6 B1407 www.turck.com • Phone: 763-553-7300 • Application Support: 1-800-544-7769 • Fax: 763-553-0708 • Turck Minneapolis, MN 55441...
  • Page 7 With the EZ-track properly installed inside the hydraulic cylinder, it may be necessary to assemble parts of the hydraulic cylinder . For assistance in this task, refer to the information provided by the cylinder manufacturer . B1407 7 www.turck.com • Phone: 763-553-7300 • Application Support: 1-800-544-7769 • Fax: 763-553-0708 • Turck Minneapolis, MN 55441...
  • Page 8 3 . This dimension applies when tap drill cannot pass through entire boss . 4 . This dimension does not conform to SAE J1926-1 . 8 B1407 www.turck.com • Phone: 763-553-7300 • Application Support: 1-800-544-7769 • Fax: 763-553-0708 • Turck Minneapolis, MN 55441...
  • Page 9: Chapter 3: Wiring

    The power supply should be dedicated to the LTX to prevent noise and external loads from affecting it . When powering up more than one LTX on a single power supply, each unit will draw approximately one watt . B1407 9 www.turck.com • Phone: 763-553-7300 • Application Support: 1-800-544-7769 • Fax: 763-553-0708 • Turck Minneapolis, MN 55441...
  • Page 10 Figure 3-2: Current Sourcing The LTX R10 is current sourcing which allows the current to flow from the EZ-track into the users equipment . 10 B1407 www.turck.com • Phone: 763-553-7300 • Application Support: 1-800-544-7769 • Fax: 763-553-0708 • Turck Minneapolis, MN 55441...
  • Page 11: Features

    5 . Short the Program Input pin to the Power Supply Common for 4 seconds . Remove the short for 1 second . Within 5 seconds, short the Programming Input pin to the Power Supply +VDC . This completes the programming process . B1407 11 www.turck.com • Phone: 763-553-7300 • Application Support: 1-800-544-7769 • Fax: 763-553-0708 • Turck Minneapolis, MN 55441...
  • Page 12 8 . Push the Zero button for 4 seconds . Release the Zero button for 1 second . Within 5 seconds, push the Span button . 12 B1407 www.turck.com • Phone: 763-553-7300 • Application Support: 1-800-544-7769 • Fax: 763-553-0708 • Turck Minneapolis, MN 55441...
  • Page 13: Specifications

    Resolution Internal 0 .00006" (1 .524 microns) Output 16-Bit Position Output 0-10 VDC, 16 Bits (65,535) resolution 4-20mA, 16 Bits (65,535) resolution B1407 13 www.turck.com • Phone: 763-553-7300 • Application Support: 1-800-544-7769 • Fax: 763-553-0708 • Turck Minneapolis, MN 55441...
  • Page 14: Part Numbering System

    Cylinder Magnet CM-R10 2 meter Cable, Right Angle Cordset WK-4 .5T-2/S618 Mounting Bracket Kit MB-R10 4 meter Cable, Right Angle Cordset WK-4 .5T-4/S618 14 B1407 www.turck.com • Phone: 763-553-7300 • Application Support: 1-800-544-7769 • Fax: 763-553-0708 • Turck Minneapolis, MN 55441...
  • Page 15: Appendix A: Troubleshooting

    4 . Using a digital voltmeter, check across Power Supply Common and customer supplied power (+VDC) on the mating end of the cable for a level between 7 and 30 VDC B1407 15 www.turck.com • Phone: 763-553-7300 • Application Support: 1-800-544-7769 • Fax: 763-553-0708 • Turck Minneapolis, MN 55441...
  • Page 16 . If voltage is between 7 to 30 VDC and the EZ-track is still inoperative, contact factory . * See Section 3 .4 page 13: Specifications for more information on power consumption . 16 B1407 www.turck.com • Phone: 763-553-7300 • Application Support: 1-800-544-7769 • Fax: 763-553-0708 • Turck Minneapolis, MN 55441...
  • Page 17 Notes: B1407 17 www.turck.com • Phone: 763-553-7300 • Application Support: 1-800-544-7769 • Fax: 763-553-0708 • Turck Minneapolis, MN 55441...
  • Page 18 Notes: 18 B1407 www.turck.com • Phone: 763-553-7300 • Application Support: 1-800-544-7769 • Fax: 763-553-0708 • Turck Minneapolis, MN 55441...
  • Page 19 Notes: B1407 19 www.turck.com • Phone: 763-553-7300 • Application Support: 1-800-544-7769 • Fax: 763-553-0708 • Turck Minneapolis, MN 55441...
  • Page 20 28 subsidiaries and over 60 representations worldwide! Printed in USA ©2015 by Turck Inc. All rights reserved. No part of the www.turck.com B1407 B 10/15 publication may be reproduced without written permission.

This manual is also suitable for:

Ez-track

Table of Contents