F15
PV Volt High
F17
Grid Volt Fault
F18
Isolation Fault
F19
Current DC Offset
F21
PV2 Over Current
F24
PV1 Over Current
F25
Relay Fault
F27
Inv Over Current
F29
Grid Freq Fault
DC Voltage Is Too High Due To
Wrong Installation
Grid Voltage Detection Within
A Period Is Anomalous
Impedance To Ground Between
Battery Positive and Negative
Is Less Than 2 MΩ
A Phase Current Waveform
That Be Detected Is Larger
Deviation
The input current of PV2 is
over rated value. May be there
is something wrong with the
hardware
The input current of PV1 is
over rated value. May be there
is something wrong with the
hardware
General error in inverter start
time, there may be damage of
relay
The inverter current is over
rated value.
The grid frequency exceeds the
set range
1.Correct The Installation (Remove
Panels)
2.Re-Flash Software
3.Replace Part Or Inverter
Change the grid voltage protection
range
1.Remove this Fault
2.Change it to another standard with
wider
protection range under authorization
Change it to another standard with
wider
protection range under authorization
1.Restart the inverter
2.If the problem persists, please
replace the inverter.
1.Restart the inverter
2.If the problem persists, please
replace the inverter.
If the problem persists, please
replace the inverter.
1.Restart the inverter to check
2.If it doesn't get back to normal
please replace inverter
Change it to another standard with
wider protection range under
authorization