1. Scope of delivery The manual provides safety guidelines, detailed planning and setup information. It provides procedures for installing the inverter and information about operation and troubleshooting of the unit. This manual does not contain details about photovoltaic (PV) panels. Please consult with system integrator for the information.
3. Introduction InfiniSolar inverter is a hybrid PV inverter which consists of Grid input, PV input, battery Omnikhyd inverter is a hybrid PV inverter which consists of Grid input, PV input, battery input, and AC output. The configuration is illustrated in Figure 1, showing the PV energy has been feed back to grid, or used to charge the battery.
2) BATTERY mode( in Figure 3) Figure 3 Under this mode, the inverter is not able to connect to the grid. Either solar power or battery power becomes major power source. When PV power is strong, the inverter will power load first and the remaining power will charge battery.
The Solar Inverter is applied with Maximum Power Point Tracking (MPPT) technology to harvest the maximum amount of energy from the solar panel. Measurement must be taken to ensure that the maximum open circuit voltage of 500 VDC is never exceeded. Please note that the maximum open-circuit voltage will occur at the lowest temperatures anticipated.
G: Intelligent slot H: Parallel connector 5. Installation 5.1 Installation location Do not mount the inverter on flammable construction materials. Mount on a solid surface High temperature may cause a power reduction due to excessive heating. Install this inverter at eye level in order to allow the LCD display to be read at all times. Dusty conditions on the unit may impair the performance of this inverter.
Page 9
WALL Figure 1 Figure 2 5.4 Ambient temperature The solar inverter can be operated in an ambient temperature between 0℃ to +40℃. 5.5 Grid Connection Measure grid voltage and frequency. It should be 230VAC, 50HZ, and single phase. Open the breaker or fuse between the inverter and utility. Connect AC wires as table 1 list. Connectors wire suggestion B:L1...
Page 10
Table 1 To prevent risk of electric shock, ensure the ground wire is properly earthed before operating the solar inverter. 5.6 Connection of PV modules Before the photovoltaic system is connected, the polarity of the PV voltage must be checked to ensure that it is correct.
Using an AC voltmeter, measure the AC open circuit utility voltage between L and N. Ensure this voltage is at approximately nominal value expected for the local utility company. Check battery voltage Ensure that battery voltage is at approximately nominal value expected for inverter(48Vdc). The line breaker and battery breaker are correctly rated Before switching on the power, check all feeders and connections again.
Indicates battery voltage or percentage. Volt: voltage, %: percentage Indicates charging current to battery. Indicates that the warning occurs. Indicates that the fault occurs. Indicates fault code in fault mode or WR for warning situation. Indicates date and time, or the date and time you set for querying energy generated.
Page 13
7.3 Query Menu Operation This display shows current values of your system. This displayed values can be changed in query menu via button operation. Press “Enter” button to enter query menu. There are seven query selections: Grid voltage or frequency of AC input Frequency, voltage, power or load percentage of AC output Input voltage or power of PV input.
Page 14
Input voltage or power of PV input. Procedure Enter Enter Enter Down Down Battery voltage or percentage. Procedure Enter Down Enter Enter Down Date and time. Procedure Page 14 of 21 Rev. A...
Page 15
Today or total energy generated. Procedure Mode of query energy generated. Energy generation display of selected day Procedure: LCD Display: Energy generation display of selected month Procedure: LCD Display: Page 15 of 21 Rev. A...
Energy generation display of selected year Procedure: Enter Down Enter Down Enter Enter Up Down Sets year Flashes Enter Returns to main menu LCD Display: Page 16 of 21 Rev. A...
Page 17
7-4. Device status & Display Status LCD Display PV module and battery are connected and working well, but it’s not connected to grid. Inverter is charging battery from PV energy. The utility icon flashes. PV module and battery are connected and working well, but it’s not connected to grid.
When PV energy is weak, PV module and the utility will power the load and charge battery. There is no PV power available and inverter is not connected to grid. All loads are powered from battery energy. The utility icon flashes. When PV energy is loss, the utility is powering the load and charging battery.
Page 19
Over voltage on Bus Under voltage on Bus Time out for Bus soft start Time out for Inverter soft start Inverter over current Over temperature Relay fault Output current sensor failure High voltage on PV module Power down DC input over current GFCI failure PV insulation failure Inverter DC current over...
10. Specifications Item Specification Comments AC input data AC start voltage 120~140Vac ±3% Auto restart voltage 194 Vac Tolerance AC input voltage range 184~265 Vac AC input voltage comeback value 194Vac / 255Vac 47.5 ~ 50.2 Hz Hz AC input frequency range AC input frequency comeback value 47.6Hz / 50.1Hz Max.
Max output current 13.6A Under the output voltage is 220VAC O/P current distortion <3% Under utility voltage THD<3% Power Factor >0.99 Battery mode output data Nominal output power 3000W Wave form Pure sine wave Nominal output voltage 220Vac Tolerance Nominal output frequency 50 Hz + 0.1Hz Tolerance...